Peripheral Devices
9836 3521 01
471
Result data:
The following data is possible to report to DC PLUS. By default only the Torque, Angle, Redundancy
Torque and the Step number is included. The other data can be selected in the reporter if wanted.
Bolt level data
This table describes the data sent to PLUS if the Bolt level data is reported
PI
Description
Value sent, PW
Comment
DM
Torque
Bolt T
MO
Torque high limit
Bolt T, high limit
Only sent if limits for Bolt T is selected in the reporter
MU
Torque low limit
Bolt T, low limit
Only sent if limits for Bolt T is selected in the reporter
RM
Redundancy
torque
-
No value is sent
DW
Angle
Bolt A
Are always sent as an integer with unit degrees. The value
is rounded to nearest integer.
WO
Angle high limit
Bolt A, high limit
Only sent if limits for Bolt A is selected in the reporter
WU
Angle low limit
Bolt A, low limit
Only sent if limits for Bolt T is selected in the reporter
RW
Redundancy
angle
-
This value is not possible to send.
ZW
Time
-
No value is sent
PH
Step number
0
The step number will always be 0 to indicate that it is bolt
data
ST
Current
-
No value is sent
GD
Gradient
-
No value is sent
Step level data
This table describes the data sent to PLUS if step level data is reported. All the step data will come from
the same step.
PI
Description
Value sent, PW
Comment
DM
Torque
SO T,
“Shut off torque”
The value reported from a “Check shut off torque” check.
The torque is multiplied by 100 and is sent as an integer (2
decimals rounded).
MO
Torque high limit
SO T, high limit
Only sent if limits for SO T is selected in the reporter
MU
Torque low limit
SO T, low limit
Only sent if limits for SO T is selected in the reporter
RM
Redundancy
torque
Peak C
The current is converted to torque.
DW
Angle
A
Are always sent as an integer with unit degrees. The value
is rounded to nearest integer.
WO
Angle high limit
A, high limit
Only sent if limits for A is selected in the reporter
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...