When the Fieldbus master wants to read or write anything via the PowerMACS process data interface it
has to follow the following basic rules:
1. Read the STS word to ensure that it is zero.
2. If not zero then write zero to the CMD word to acknowledge that the previous data/result has been
read.
3. Wait for the STS word to become zero. This is PowerMACS way to indicate that it is ready to
receive a new command.
4. Write the wanted command to the CMD word.
5. Wait for the high byte (bit 15...8) of the STS word to become equal to the written in the CMD word.
This is PowerMACS way to acknowledge that the command is received and executed.
6. Check that the low byte (bit 7...0) of the STS word is zero. This indicates that the command was
executed successfully. If reading, the output data is now valid.
7. When finished, with reading of data and/or the STS word, write zero to the CMD word to
acknowledge that the result is read.
Example on how to read process data:
To read Process data the fieldbus master should use the following handshake sequence:
Fieldbus master
PowerMACS
1
Sets CMD = R + DataType
2
Loads data in the OUT area
Sets STS = R + Da Status
3
Reads data from the OUT area
Sets CMD = 0
4
Sets STS = 0
5
Waits until STS = 0
Example on how to write process data:
To write Process data the fieldbus master should use the following handshake sequence:
Fieldbus master
PowerMACS
1
Writes data in the IN area
Sets CMD = W + DataType
2
Reads data from the IN area
Sets STS = W + Da Status
3
Sets CMD = 0
4
Sets STS = 0
5
Waits until STS = 0
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...