Set Up and Maintenance
9836 3521 01
179
During a cold start of the System TC checks the status of its own local database and the backup copy
stored on TC 2. Depending of their respective status the following cases can arise during system start-up:
Case
Status of
setup in the
System TC
Status of the
backup in
TC 2
Action
1
Empty
Empty
Only the System TC is started. A setup must be
downloaded using ToolsTalk PowerMACS.
2
Empty
Ok
First the backup setup is copied from TC 2 to the System
TC.
Then the system starts using the copied setup.
3
Ok
Empty
First the setup is copied from the System TC to TC 2.
Then the system starts using setup originally stored on the
System TC.
4
OK
OK and identical
to the setup in
the System TC
The system does a normal start.
5
OK
OK but
not
identical to the
setup in the
System TC
The system is not started
. This situation is indicated to
the operator in the following two ways:
On the System TC the display will say backup setup
differs.
When trying to go connect with ToolsTalk PowerMACS
it will refuse to connect and only display the "Resolve
Procedure" form describing the situation.
See chapter: Replacement of TCs below, for how to
resolve the ambiguity.
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...