Tightening
9836 3521 01
315
6.5.3.6 Cross Thread and Gradient
Parameters
: Torque level T1, Torque level T2, Min angle, Max angle
Function
:
Measures the angle from the point where torque passes Torque level T1 to the point where
torque passes Torque level T2. Checks that the measured angle, A, is between Min angle
and Max angle.
Min angle or Max angle can be left empty meaning that the respective test is disabled. Note
that at least one of them must be configured.
Diagram
:
T1
T2
Angle
Torque
T1
Torque Level T1
Amin
Angle min
T2
Torque Level T2
Amax
Angle max
A
Measured angle from T1 to T2
Step
Amax
Amin
A
Alarms
:
Cross thread restriction (CROSSTR) if A > Max angle. Cross gradient too high restriction
(CROSSGR) if A < Min angle.
Trace
:
Two lines are shown in Torque vs. Angle view. The horizontal line represents the T2 level
and it starts when T1 is passed and ends after Amin degrees. The vertical line represents
the point where Amax degrees are passed after T1. The step fails if any of the lines is
crossed. Restriction limits must be enabled in the trace form (see View of trace curves).
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...