Tightening
9836 3521 01
321
Torque in Time
window
Step or Zone
Step start
Zone start
Zone started
Check Mean T
Step or Zone
Angle
Torque
Time
Step start
Angle
Torque
Time
Zone start
Zone ended
Check Angle
Step or Zone
Start condition:
Torque
Step start (AS1)
Shut off previous (AS2)
Peak angle previous
(AS3)
Start condition:
Torque
Zone start
Zone started
Stop condition:
Shut off
Shut off previous
Peak Angle
Final Angle
Torque
Stop condition:
Zone end
Torque
Zone ended (if stop
condition is Zone
End)
Check Post view
Torque
Step
Step start
Check T/T3
Step or Zone
Step start
Zone start
Zone ended
Check shut off
Torque
Step or Zone
Step start
Zone start
Zone ended
Check torque rate
Step or Zone
Step start
Zone start
Zone started
Check Time
Step or Zone
Step start
Zone start
Zone started
Check Yield point
Step
Step start
Check Stick Slip
Step
Step start
Check Delta T
Step or Zone
Step start
Zone start
Zone started
Low Spot T
Step or Zone
Step start
Angle
Zone start
Angle
Zone started
Check Position
Step
Step start
6.5.4.1 Result values from checks
For each check it is possible to select the cycle data variable it shall use to store the result. Each check
type has its own specialized variables that can only be used for that check type (e.g.
Peak T, Peak T1,
Peak T2
and
Peak T3
for a peak torque check). There are also general variables available that can be
used for all check types.
The specialized variables can only be used in the correct check type with the correct channel selection for
torque or angle. For example
Peak T
can only be used in a peak torque check with the torque channel set
to
Auto
.
A2
can only be used by an angle check with the angle channel set to
Angle 2
, etc.
Two sets of general variables are available, one on step level and one on bolt level, with 80 variables in
each set. The variables on step level are named
Step var. 01
,
Step var. 02
, etc, and the variables on bolt
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...