Tightening
9836 3521 01
383
Bolt Status variables can take one of the following values:
Mnemonic
Num. Id
Description
OK
0
Successful. No repairs have been made.
OKR
1
Successful. Errors have occurred but have been repaired
NOK
2
Not successful. This bolt failed to execute a step either due to a restriction, a
check or that any other fatal error occurred.
TERMNOK
3
Not successful. An error occurred while running a terminate sequence (i.e. the
steps specified using “Terminate with step” on the Reject tab for a step). The
execution of steps was terminated when the error was found
NOKRM
4
Not successful
only due to reject management
. The bolt did not fail to execute a
step but was ordered to terminate, or not to finish the program, as a reject
management action.
6.7.2
Station level result variables
The Station level contains information concerning the station that runs the tightening.
Variable name
Description
Data No
A device unique sequence number. This number is incremented by one for each cycle
data reported over the device in question. This number can be used to detect missing
cycles.
Station
The name of the station. See System for how to set or change the name of a station. Max.
20 ASCII characters.
Station No
The number of the station. The first station in the system is 1.
Time
The date and time when the cycle was started.
Wp ID
Work piece Identity. Supplied to station from an ID device (see ID device Set Up) or set by
the PLC using the IDSTRING output (Station variables). Max. 40 ASCII characters.
Mode
The name of the mode that was executed. Set using The Mode Table form. Max. 20 ASCII
characters.
Mode No
The number of the mode that was executed.
Status
Total status for the station: See chapter: Statuses for possible values.
Total
Total number of cycles executed during the current shift. See Shift Reports and Shift Set
Up for a description of shifts.
Total OK
Total number of cycles that ended OK or OKR during the current shift. See Shift Reports
and Shift Set Up for a description of shifts.
Total NOK
Total number of cycles that ended NOK or TERMNOK during the current shift. See Shift
Reports and Shift Set Up for a description of shifts.
Free Str
The value of the PLC output FREESTRING when the cycle was started (see Station
variables).
Free No 1
The value of the PLC output FREENUM1 when the cycle was started (see Station
variables).
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...