Peripheral Devices
598
9836 3521 01
8.15.1
Interface definition input
The input map definition for signals to PowerMACS is according to the following table:
Word
Byte
Bit
Name in DeviceNet map
Name of
IO signal
Pass through
IO signal
0
0
0
Green Light (Pass through to IO)
DO_GM_GreenLight
1
Yellow Light (Pass through to
IO)
DO_GM_YellowLight
2
Red Light (Pass through to IO)
DO_GM_RedLight
3
Alarm Horn (Pass through to IO)
DO_GM_AlarmHorn
4-6
Spindle
– Mode Set Code (1-8)
DI_GM_ParSet1 - 4
DO_GM_ParSet1 - 4
7
Spare
1
0
Start Cycle
DI_GM_Start
1
Reverse
DI_GM_Reverse
2
Error Proofing Ready (EPR)
DI_GM_EprIn
DO_GM_EprOut
3
Spindle
– Stop/Disable
DI_GM_StopDisable
4-7
Spare
1
0-1
N/A
Spare
2-3
0-3
N/A
PVI number
The inputs are used as follows (all signals have positive logic where active is 1 and passive is 0):
Green Light:
This signal is just passed through to PowerMACS discrete I/O interface (local I/O).
Yellow Light:
This signal is just passed through to PowerMACS discrete I/O interface (local I/O).
Red Light:
This signal is just passed through to PowerMACS discrete I/O interface (local I/O).
Alarm Horn:
This signal is just passed through to PowerMACS discrete I/O interface (local I/O).
Spindle
– Mode Set Code
: Used to choose the mode that should be run when
Start Cycle
goes high
(could be 0 to 7 witch will correspond to Mode 1 to 8 in the stations Mode Table). This
signal is sampled continuously as long as no cycle is running and is echoed to the output
signal
Spindle
– Mode Set Code
.
Reverse:
When this signal is 1 it will override the value of
Mode Set Code
and force mode to the
value 9 for a reverse program. This signal is sampled continuously as long as no cycle is
running.
Start Cycle:
Starts the tightening cycle if the
Error Proofing Ready
signal has switch from 0 to 1 since
the last cycle and
Spindle - Stop/Disable
is low. The cycle is started using the current
value of
Spindle
– Mode Set Code
or
Reverse
. Immediately when starting the cycle all
green, yellow and read indication lamps are turned off (for the DeviceNet and as well as the
I/O interface).
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...