Peripheral Devices
9836 3521 01
603
Whether torque and angle are considered OK or not for a bolt is decided by the data in the corresponding
Bolt level result variables "Errors". The below tables shows which error bits that are used, and for what
purpose.
TORQUE status
Bit in "Errors"
< ZDR
TTNOTRM (Threshold torque not reached for angle monitoring, see chapter: Monitoring
Check
REHIT
CROSSGR (Cross gradient restriction exceeded, see chapter: Cross Thread and Gradient)
> Remove limit
RFTLIMRE (Remove Fastener Torque Limit REeached, see chapter: Program )
Low
TLM (Final torque too low during monitoring, see chapter: Monitoring Check
High
THM (Final torque too high during monitoring, see chapterMonitoring Check
OK
True
only
if the status of the bolt is OK
ANGLE status
Bit in "Errors"
Low
ALM (Angle too low during monitoring, see chapter: Monitoring Check
High
AHM (Angle too high during monitoring, see chapterMonitoring Check
OK
True
only
if the status of the bolt is OK
If several of the above errors occur during a cycle they are prioritised so that the worse, or most "red",
error wins. That is, the priority order is (most significant error has lowest number):
1. The
Red
lamp only
2. The
Yellow
+
Red
lamps
3. The
Yellow
lamp
4. The
Green
lamp.
Note!
If a bolt ends with status NOK and none of the errors listed above are at hand, or the control
strategy is undefined, then none of the lamps will be switched on.
This situation can occur if the monitoring checks and restrictions listed above are not used, or if the
program does not include any step defining a control strategy.
The monitoring checks must always be evaluated, thus
Ignore monitoring errors when step ends
NOK
cannot be checked.
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...