Tightening
290
9836 3521 01
6.5.2.13 TD - Run until Torque has decreased
Step type Id:
10
Parameters:
T (Torque), A (Angle), DIR (Direction)
Function
:
Run spindle, in DIR direction, until angle A is reached. The rotation continues but from that
point the torque is measured. The step stops when the measured torque is less than, or
equal to, T.
Diagram
:
Angle
Torque
A
Angle
T
Torque
Step
A
T
Trace
:
Torque T is shown as a horizontal line from step start to step stop in trace when Torque vs.
Time is selected. Control parameters must be enabled in the trace form (see