Set Up and Maintenance
9836 3521 01
193
Single torque transducer
If you are using the “Single run” option, run a program with a “Diagnostic” step with spindle
functional test enabled to get a new zero offset reading and compensation from the spindle.
Make at least 10 tightenings to the desired final torque and record the results from the reference
transducer (Xref) and the reported final torque from the spindle (X)
Calculate the mean reference torque (Xmeanref) and the mean final torque (Xmean).
Xmeanref = SXrefn / n
where “n” is the number of tightenings
Xmean = SXn / n
where “n” is the number of tightenings
Adjust the spindle parameter Scale factor for channel Torque 1 (Ts) (see Spindle Set Up,
Calibration) with the calculated value. Increase the Scale factor in order to decrease the true torque
and vice verse.
Ts-new = Ts-old x Xmeanref / Xmean
If you are using the “Single run” option, run a program with a D - Diagnostic Step in order to get a
new zero offset reading and compensation.
Run a new test series in order to confirm the correction.
If a torque scatter test is required (Standard deviation, Cp, Cpk, Cmk, CAM……) a minimum of 20
tightenings are needed.
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...