Basic Functions
62
9836 3521 01
When connected to a system the Station and Bolt nodes will display certain colors depending on the last
status.
Color
Status
Green
OK - Idle after OK cycle
Red
NOK - Idle after NOK cycle
Orange
NOKRM - Idle NOK only due to reject management after a cycle. For bolts only
Yellow
Running cycle
Blue
Bolt is disconnected. This color is only used if the checkbox
Display disconnected bolts with blue
color
in the Options form is checked.
If not checked then disconnected OK bolts will be green and disconnected NOK bolts will be red.
For bolts only
Below the actual tree are the particular
Details
for the currently selected item listed. Use the
Details
window to edit data for an item. By default the Details window is placed below the actual system tree but it
can be placed anywhere on the screen by drag & drop.
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...