3D Systems, Inc.
91
p/n: 15-D100, rev. D
Step by Step Calibration
With a step by step calibration, the end user has more control
over the individual steps. This way they can, for example, only
perform the verification measurements to check the status of
the current calibration factors.
1.
Click Perform verification measurements
.to verify the
status of the current calibration factors. Verification will
take +/- 5 min.
• After successful verification, a confirmation message
will appear.
2. Click
Perform Calibration Measurements
. The automated
measurement will take a couple of minutes (30 sec per
data point at least). Depending on the type of measurment
head the measurement can take up to 30 minutes. This
long measurement significantly improves the accuracy and
repeatability of the calibration.
Note: An error message will appear if the laser is
not ready.
• If verification was not successful, the message will say
the tolerances have been exceeded and a calibration
needs to be performed.