SYSTEM USE
5.1 Start up DMP Flex 350
1. The DMP Flex 350 system must be plugged into the facility
power.
2. None of the
Emergency off
buttons (5) located on the
machine must be engaged.
3. Enable switch (2) must be properly connected. If not, the
safety circuit will be activated.
4. Turn on the main power switch (1) on the electrical cabinet
of the printer.
5. Turn on the 24V DC power switch (3) on the rear control
panel of the printer.
6. Check and, if closed, open the main valves (4) for argon and
compressed air on the right side of the electrical cabinet.
For the recommended argon and compressed air pressure
values, see
§6.3.3
.
7. Make sure the machine in set in
Operator mode
(6).
8. Press ON button (7).
9. Press PC ON button (8).