3D Systems, Inc.
89
p/n: 15-D100, rev. D
5. Switch on the power meter device. The battery of the device
must be sufficiently loaded.
6. Set the readout device to the correct wavelength (
1064 Nm
).
7. Use duct tape to fix the cables to the frame of the process
chamber.
8. Close the printer door and handtighten the door bolt in the
upper right corner.
Caution: Do not crush the cable between the
printer door and the frame of the process
chamber.
9. Use laser safety tape (
p/n: 80-4392
Black Aluminum Foil
Tape 2” x 81’) to seal of the gap between printer door and
frame.
10. Turn the service key ON.
11. Open the DMP toolbar and log in as an
Engineer
.
12. Open DMP Control. In the task bar, click
Machine
>
Laser
>
Laser Power Calibration
to open the Laser power
calibration window.
13. When the device is connected for the first time and no
drivers are installed, an error message will appear.
14. Browse to the Ophir website indicated in the error message
(url linked here) to download the StarLab software.
Caution: Disconnect the power meter from the
USB port when installing the StarLab software to
avoid driver issues.
Note: Remove the StarLab icon from the computer
desktop as this application will never be used.