7-16
IM CW240E
Start of integration:
START
&STOP
Press the START&STOP key once.
Integration is started according to the setting of the integration starting method.
Starting method : MANUAL (press the START&STOP key to start integration.)
TIME (lets you enter the date and time of start of integration) ---
Integration is on standby up to the start time.
JUST (starts integration at the optimum time) --- Integration is on
standby up to the start time.
Integration starts according to the time when the START&STOP
key is pressed and the interval time.
During integration:
When integration measurement starts, the LED lights up, indicating INTEG is being made.
Integration measured data is saved according to the data save settings.
End of integration:
Integration ends according to the setting of the integration stopping method.
Stopping method: MANUAL (press the START&STOP key to stop integration)
TIME
(lets you enter the date and time of the end of integration)
TIMER
(lets you set the time from the start, and integration ends when
the set time expires.)
Forced end
: Even when the stopping method has been set to TIME or TIMER, you
can press the START&STOP key to stop integration.
To switch the load to be displayed:
F
2
The load changes each time the F2 key is pressed.
Measured values are displayed on a load basis.
(The display varies depending on the setting of wiring or number of loads.)
7.3 Measuring Electric Energy