Power save options
Opens the power save settings dialog. The power save options
menu option is only available when the radar source is in standby
mode.
The settings made in the power save settings dialog are applied
when the Set option is selected.
Use the power save settings dialog to specify the number of scans
while transmitting and the amount of time the radar source will be
in standby, during power save mode.
When in standby during power save mode, the radar image freezes
and becomes grey-scaled. When the specified standby time period
ends, the radar will commence transmitting until the completion of
the number of scans specified is reached. The radar will then go into
power save standby again. The power save cycle will continue until
the radar source is in standby mode, transmit mode or powered off.
If a radar control is adjusted during the standby time period, the
radar will commence transmitting until the completion of the
number of scans specified is reached.
Guard Zone alarms remain available while power save mode is
active. If an alarm is triggered while in power save mode, the radar
will remain transmitting indefinitely. Power save mode will need to
be re-enabled manually in this event.
Power save settings will be applied to both radar ranges in dual
range mode.
Transmit
The scanner is on and transmitting. Detected targets are drawn on
the radar PPI (Plan Position Indicator).
Ú
Note:
You can also put the radar in transmit mode from the
system controls dialog.
110
Radar
| GO XSE/XSR Operator Manual
Summary of Contents for GO XSE Series
Page 1: ...GO XSE XSR Series OPERATOR MANUAL ENGLISH www simrad yachting com ...
Page 2: ......
Page 16: ...16 Contents GO XSE XSR Operator Manual ...
Page 62: ...62 Waypoints routes and tracks GO XSE XSR Operator Manual ...
Page 97: ...Trolling motor autopilot GO XSE XSR Operator Manual 97 ...
Page 240: ......
Page 241: ......