To configure the port as nni attribute
uni
To configure the port as uni attribute
Each physical port of a switch has UNI/NNI attribute. By default, all 10M/100M ports are
configured as UNI ports and other ports are configured as NNI ports. You can also change
the UNI/NNI attribute of each port via configuration.
By default, UNI ports are shutdown, and cannot communicate with each other. But
communication can be performed normally between UNI ports and NNI ports and also
between NNI and NNI ports. You can also enable some UNI ports to communicate with
each other via configuration.
uni-isolate { community | isolated }
This command is used to configure whether UNI ports can communicate with each other.
uni-isolate { community | isolated }
Syntax
Description
community
UNI ports can communicate with each other
isolated
UNI ports cannot communicate with each other
Monitoring & Maintaining
M o n i t o r i n g Co m ma n d s
In order to display basic information of a port (such as link status, rate, duplex, and UNI type),
users can switch to the privilege user mode and run
show port [portlist] [configuration]
.
Command
Description
show port
[
portlist
] [
configuration
]
To display basic information of a port
The displayed information includes description information,
link status, rate, duplex, and UNI type.
show port
[
portlist
]
statistics
To monitor the statistics information of the port
show storm-control
[
portlist
]
To monitor the storm control of the port
The displayed information includes the enabling status of unknown unicast
packets, unknown multicast packets, and broadcast packets
show port-type
{
uni|nni
} [
portlist
]
To monitor the UNI/NNI attribute of the port
The displayed information includes the UNI/NNI attribute of the port and
whether the ports are isolated
Summary of Contents for 065-7434
Page 1: ...24 Port 10 100 L3 Switch Model 065 7434 Configuration Guide Revision A1 ...
Page 245: ...245 SIGNAMAX LLC www signamax eu Application Example Example of configuring DHCP Snooping ...
Page 302: ...302 SIGNAMAX LLC www signamax eu Default status no switching interface ...
Page 368: ......
Page 655: ...287 SIGNAMAX LLC www signamax eu Sub VLAN members in the system ...