102
SIGNAMAX LLC • www.signamax.eu
no Loopback
To cancel loop check
config-port-×/×,
config-port-range
port-type {uni|nni}
To configure the UNI/NNI type of the port
config-port-×/×,
config-port-range
no port-type
To recover the default UNI/NNI type of the port
config-port-×/×,
config-port-range
uni-isolate { community | isolated }
To configure whether UNI ports communicate
with each other
config-port-×/×,
config-port-range
shutdown
This is command is used to configure the management status of the port. After one port
is disabled, it does not send or receive any frame. Therefore, it does not have any
function. The port status includes UP and DOWN. When one port is disabled, its status
must be DOWN.
To disable one port, use the command. Otherwise, use the no format.
shutdown
no shutdown
Note
Even a port is no shutdown; its status may not be up. The status also depends on other
situations, for example, the network cable is not inserted or the port is closed temporarily.
Description
For memorizing easily, you can configure the description information for a port. For
example, a port is allocated to company A, and you can configure its description
information as “company A”. Description information consists of up to 240 characters and
space can be input among characters.
By default, there is no description information for a port.
description
string
no description
Command
Description
string
The character string of the description information of a port
Default status: No description information
duplex
This command is used to configure duplex parameter on one port.
duplex
{auto|full|half}
Summary of Contents for 065-7434
Page 1: ...24 Port 10 100 L3 Switch Model 065 7434 Configuration Guide Revision A1 ...
Page 245: ...245 SIGNAMAX LLC www signamax eu Application Example Example of configuring DHCP Snooping ...
Page 302: ...302 SIGNAMAX LLC www signamax eu Default status no switching interface ...
Page 368: ......
Page 655: ...287 SIGNAMAX LLC www signamax eu Sub VLAN members in the system ...