60
SIGNAMAX LLC • www.signamax.eu
port 0/6
port-type uni
uni-isolate isolated
shutdown
ethernet uni-id UNI-port-0/6
ethernet uni-type bundling
exit
port 0/7
port-type uni
uni-isolate isolated
shutdown
ethernet uni-id UNI-port-0/7
ethernet uni-type bundling
exit
port 0/8
port-type uni
uni-isolate isolated
shutdown
duplex full
speed 100
ethernet uni-id UNI-port-0/8
ethernet uni-type bundling
exit
!end
L o a d o f Co n f i g u r a t i o n Fi l e
The configuration file of a Signamax switch can be edited in a text editor (for example,
WordPad) according to the format prescribed in the above section, and can be downloaded to
a switch via FTP or TFTP. This operation can be used by terminal users or via Telnet remote
login.
The following example is given to explain how to download the switch configuration file via FTP:
Step 1: Edit the configuration file named config on a PC
Step 2: Enable the FTP SERVER on the PC;
Step 3: Execute the command ftpcopy in the file configuration mode of the switch to
download the configuration file from the PC;
As follows: