threshold of error frame checking of Ethernet
OAM link monitoring
none
To set the error response processing of error
frame checking of Ethernet OAM link monitoring
as not process
error-disable-interface
To set the error response processing of error
frame checking of Ethernet OAM link monitoring
as shutdown the interface
【
【
【
【
Default Status
】
】
】
】
By default, do not process the error response.
ethernet oam link-monitor frame-seconds window
This command is used to set the window period of error frame second
checking of Ethernet OAM link monitoring. Error frame second is that if
there are error frames within a second, the second is called error frame
second. Checking error frame second is to check whether there are error
frame seconds within a period. If there are error frame seconds and the
threshold is exceeded, report error.
The no format of the command is used to recover the default value.
ethernet oam link-monitor frame-seconds window
window-value
no ethernet oam link-monitor frame-seconds window
[
window-value
]
Syntax
Description
window-value
To set the window period of error frame second
checking of Ethernet OAM link monitoring. The
value range is 1-60 and the unit is second.
【
【
【
【
Default Status
】
】
】
】
window-value
: 1s
ethernet oam link-monitor frame-seconds threshold
This command is used to set the threshold of error frame second
checking of Ethernet OAM link monitoring. Error frame second is that if
there are error frames within a second, the second is called error frame
second. Checking error frame second is to check whether there are error
frame seconds within a period. If there are error frame seconds and the
threshold is exceeded, report error.
The no format of the command is used to recover the default value.
ethernet oam link-monitor frame-seconds threshold {low | high}
{none |
threshold-value
}
no ethernet oam link-monitor frame-seconds threshold {low | high}
[none |
threshold-value
]
Syntax
Description
low
To set the low threshold of error frame second
checking of Ethernet OAM link monitoring
high
To set the high threshold of error frame second
Summary of Contents for 065-7434
Page 1: ...24 Port 10 100 L3 Switch Model 065 7434 Configuration Guide Revision A1 ...
Page 245: ...245 SIGNAMAX LLC www signamax eu Application Example Example of configuring DHCP Snooping ...
Page 302: ...302 SIGNAMAX LLC www signamax eu Default status no switching interface ...
Page 368: ......
Page 655: ...287 SIGNAMAX LLC www signamax eu Sub VLAN members in the system ...