A Appendix
334
7ST6 Manual
E50417-G1176-C251-A3
13872
AR thermal trip:ON/OFF via Tele-
gram (AR TH ON/OFFtel)
Auto Reclose
IntSP
*
*
*
LED
BO
13873
AR thermal trip:ON/OFF via
Binary Input (AR TH ON/OFF BI)
Auto Reclose
IntSP
*
*
*
LED
BO
13874
>AR: BLOCK 2nd-nth cycle (>AR
BLK >1st)
Auto Reclose
SP
on
off
on off
*
LED BI
BO
40
48
1
Yes
13875
AR thermal trip:Time Out Dead
time (AR TH TO Tdead)
Auto Reclose
OUT
on
off
*
*
LED
BO
13876
AR thermal trip:dynam. blocked
(AR TH dyn Blk)
Auto Reclose
OUT
*
*
m
LED
BO
40
97
1
Yes
13877
AR Dead time is running (AR
Dead Time)
Auto Reclose
OUT
*
on
*
LED
BO
40
72
2
Yes
13878
AR 2nd cycle or higher is running
(AR >1st cycle)
Auto Reclose
OUT
*
on
*
LED
BO
40
66
2
Yes
13879
AR CLOSE command 1st cycle
(AR Close 1st)
Auto Reclose
OUT
*
*
*
LED
BO
128
128
1
No
13880
AR CLOSE command 2nd cycle
or higher (AR Close >1st)
Auto Reclose
OUT
*
*
*
LED
BO
128
129
1
No
13881
AR ON/OFF via Telegram (AR
ON/OFF TEL)
Auto Reclose
IntSP
on
off
*
*
LED
BO
13882
AR blocked by failure direction
(AR BLK DIR)
Auto Reclose
OUT
*
on
*
LED
BO
40
58
2
Yes
13883
AR blocked by max. current (AR
BLK I MAX)
Auto Reclose
OUT
*
*
*
LED
BO
40
57
2
Yes
13884
AR blocked by BF (AR BLK BF)
Auto Reclose
OUT
*
*
*
LED
BO
40
56
2
Yes
13885
AR blocked by manual closing
(AR BLK MC)
Auto Reclose
OUT
*
*
*
LED
BO
40
54
1
Yes
13886
AR enable Zone Z1 (AR EN Z1)
Auto Reclose
OUT
*
*
*
LED
BO
40
61
1
Yes
13887
AR enable Zone Z1B (AR EN
Z1B)
Auto Reclose
OUT
*
*
*
LED
BO
40
62
1
Yes
13888
AR enable Zone Z1L (AR EN
Z1L)
Auto Reclose
OUT
*
*
*
LED
BO
40
63
1
Yes
13889
AR after thermal trip cannot start
(AR TH T Reclaim)
Auto Reclose
OUT
on
off
*
*
LED
BO
40
95
1
Yes
13890
Distance Prot. Picked up in Zone
Z1B (Dis PU Z1B)
Distance prot.
OUT
*
on
*
LED
BO
13891
Distance Prot. Picked up in Zone
Z1L (Dis PU Z1L)
Distance prot.
OUT
*
on
*
LED
BO
13892
Picked up di/dt function in Zone
Z2 (Dis PU Z2di/dt)
Distance prot.
OUT
*
on
*
LED
BO
138
160
2
Yes
13893
Picked up du/dt function in Zone
Z2 (Dis PU Z2du/dt)
Distance prot.
OUT
*
on
*
LED
BO
138
164
2
Yes
13894
Picked up di/dt function in Zone
Z3 (Dis PU Z3di/dt)
Distance prot.
OUT
*
on
*
LED
BO
138
161
2
Yes
13895
Picked up du/dt function in Zone
Z3 (Dis PU Z3du/dt)
Distance prot.
OUT
*
on
*
LED
BO
138
165
2
Yes
13896
Picked up in Zone Z3 (short cir-
cuit) (Dis PU Z3K)
Distance prot.
OUT
*
on
*
LED
BO
138
129
2
Yes
13897
Picked up in Zone Z3 (overload)
(Dis PU Z3L)
Distance prot.
OUT
*
on
*
LED
BO
138
133
2
Yes
13900
Distance Protection TRIP in Zone
Z1B (Dis TRIP Z1B)
Distance prot.
OUT
*
*
*
LED
BO
28
118
2
No
13901
Distance Protection TRIP in Zone
Z1L (Dis TRIP Z1L)
Distance prot.
OUT
*
*
*
LED
BO
28
119
2
No
13903
Dist. Prot. TRIP Zone Z3 (short
circuit) (Dis TRIP Z3K)
Distance prot.
OUT
*
*
*
LED
BO
138
195
2
No
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
Ev
ent Log
O
N
/O
FF
T
rip (
Faul
t)
Log On/
O
ff
G
round
Fault Log ON/
O
FF
M
a
rk
e
d
i
n
O
s
ci
ll.
Re
c
o
rd
LED
B
ina
ry
I
n
pu
t
Function
Key
Rela
y
Chatte
r Suppr
e
ssion
Ty
p
e
In
form
ati
on Nu
mbe
r
Dat
a
Un
it
Ge
ne
ra
l Int
e
rro
ga
ti
on
www
. ElectricalPartManuals
. com