A.9 Information List
323
7ST6 Manual
E50417-G1176-C251-A3
5
>Reset LED (>Reset LED)
Device
SP
*
*
*
LED BI
BO
7
>Setting Group Select Bit 0 (>Set
Group Bit0)
Change Group
SP
*
*
*
LED BI
BO
8
>Setting Group Select Bit 1 (>Set
Group Bit1)
Change Group
SP
*
*
*
LED BI
BO
11
>User defined annunciation 1
(>Annunc. 1)
P.System Data 1
SP
*
*
*
LED BI
BO
128
27
1
Yes
12
>User defined annunciation 2
(>Annunc. 2)
P.System Data 1
SP
*
*
*
LED BI
BO
128
28
1
Yes
13
>User defined annunciation 3
(>Annunc. 3)
P.System Data 1
SP
*
*
*
LED BI
BO
128
29
1
Yes
14
>User defined annunciation 4
(>Annunc. 4)
P.System Data 1
SP
*
*
*
LED BI
BO
128
30
1
Yes
15
>Test mode (>Test mode)
Device
SP
ON
OFF
*
*
LED BI
BO
135
53
1
Yes
16
>Stop data transmission
(>DataStop)
Device
SP
*
*
*
LED BI
BO
135
54
1
Yes
51
Device is Operational and Pro-
tecting (Device OK)
Device
OUT
ON
OFF
*
*
LED
BO
138
32
1
Yes
52
At Least 1 Protection Funct. is
Active (ProtActive)
P.System Data 2
IntSP
ON
OFF
*
*
LED
BO
128
18
1
Yes
55
Reset Device (Reset Device)
Device
OUT
*
*
*
LED
BO
128
4
1
No
56
Initial Start of Device (Initial Start) Device
OUT
ON
*
*
LED
BO
128
5
1
No
60
Reset LED (Reset LED)
Device
OUT_
Ev
on
*
LED
128
19
1
No
67
Resume (Resume)
Device
OUT
ON
*
*
LED
BO
135
97
1
No
68
Clock Synchronization Error
(Clock SyncError)
Device
OUT
ON
OFF
*
*
LED
BO
69
Daylight Saving Time (DayLight-
SavTime)
Device
OUT
ON
OFF
*
*
LED
BO
70
Setting calculation is running
(Settings Calc.)
Device
OUT
ON
OFF
*
*
LED
BO
128
22
1
Yes
71
Settings Check (Settings Check)
Device
OUT
*
*
*
LED
BO
72
Level-2 change (Level-2 change) Device
OUT
ON
OFF
*
*
LED
BO
73
Local setting change (Local
change)
Device
OUT
*
*
110
Event lost (Event Lost)
Device
OUT_
Ev
on
*
LED
135
130
1
No
113
Flag Lost (Flag Lost)
Device
OUT
ON
*
m
LED
BO
135
136
1
Yes
125
Chatter ON (Chatter ON)
Device
OUT
ON
OFF
*
*
LED
BO
135
145
1
Yes
126
Protection ON/OFF (via system
port) (ProtON/OFF)
P.System Data 2
IntSP
ON
OFF
*
*
LED
BO
140
Error with a summary alarm
(Error Sum Alarm)
Device
OUT
ON
OFF
*
*
LED
BO
128
47
1
Yes
144
Error 5V (Error 5V)
Device
OUT
ON
OFF
*
*
LED
BO
135
164
1
Yes
157
Failure of main circuit breaker
(Fail. MAIN CB)
Breaker Failure
OUT
on
off
*
*
LED
BO
138
73
1
Yes
158
Failure of outdoor temp. sensing
(Fail.TEMPSENS)
Device
OUT
on
off
*
*
LED
BO
138
234
1
Yes
160
Alarm Summary Event (Alarm
Sum Event)
Device
OUT
*
*
*
LED
BO
128
46
1
Yes
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
Ev
ent Log
O
N
/O
FF
T
rip (
Faul
t)
Log On/
O
ff
G
round
Fault Log ON/
O
FF
M
a
rk
e
d
i
n
O
s
ci
ll.
Re
c
o
rd
LED
B
ina
ry
I
n
pu
t
Function
Key
Rela
y
Chatte
r Suppr
e
ssion
Ty
p
e
In
form
ati
on Nu
mbe
r
Dat
a
Un
it
Ge
ne
ra
l Int
e
rro
ga
ti
on
www