A.9 Information List
331
7ST6 Manual
E50417-G1176-C251-A3
6605
>First catenary is active (>Cat.1
active)
Therm. Overload
SP
*
*
*
LED BI
BO
6616
First catenary is active (Cat. 1
active)
Therm. Overload
IntSP
on
off
*
*
LED
BO
138
225
1
Yes
6617
Second catenary is active (Cat. 2
active)
Therm. Overload
IntSP
on
off
*
*
LED
BO
138
226
1
Yes
6618
Third catenary is active (Cat. 3
active)
Therm. Overload
IntSP
on
off
*
*
LED
BO
138
227
1
Yes
6854
>Trip circuit superv. 1: Trip Relay
(>TripC1 TripRel)
TripCirc.Superv
SP
on
off
*
*
LED BI
BO
6855
>Trip circuit superv. 1: Breaker
Relay (>TripC1 Bkr.Rel)
TripCirc.Superv
SP
on
off
*
*
LED BI
BO
6861
Trip circuit supervision OFF
(TripC OFF)
TripCirc.Superv
OUT
on
off
*
*
LED
BO
6865
Failure Trip Circuit (FAIL: Trip cir.) TripCirc.Superv
OUT
on
off
*
*
LED
BO
128
36
1
Yes
6866
TripC1 blocked: Binary Input is
not set (TripC1 ProgFAIL)
TripCirc.Superv
OUT
on
off
*
*
LED
BO
7151
Overcurrent is switched OFF
(O/C OFF)
Overcurrent
OUT
on
off
*
*
LED
BO
138
208
1
Yes
7161
Overcurrent PICKED UP (O/C
PICKUP)
Overcurrent
OUT
*
*
*
LED
BO
64
61
2
Yes
7191
Overcurrent Pickup I>> (O/C
PICKUP I>>)
Overcurrent
OUT
*
on off
*
LED
BO
138
210
2
Yes
7192
Overcurrent Pickup I> (O/C
PICKUP I>)
Overcurrent
OUT
*
on off
*
LED
BO
138
209
2
Yes
7201
O/C I-STUB Pickup (I-STUB
PICKUP)
Overcurrent
OUT
*
on off
*
LED
BO
138
211
2
Yes
7211
Overcurrent General TRIP
command (O/C TRIP)
Overcurrent
OUT
*
*
*
LED
BO
64
111
2
No
7221
Overcurrent TRIP I>> (O/C TRIP
I>>)
Overcurrent
OUT
*
on
*
LED
BO
138
214
2
No
7222
Overcurrent TRIP I> (O/C TRIP
I>)
Overcurrent
OUT
*
on
*
LED
BO
138
213
2
No
7235
O/C I-STUB TRIP (I-STUB TRIP) Overcurrent
OUT
*
on
*
LED
BO
138
215
2
No
7345
CB-TEST is in progress (CB-
TEST running)
Testing
OUT
on
off
*
*
LED
BO
153
45
1
Yes
7346
CB-TEST canceled due to Power
Sys. Fault (CB-TSTstop FLT.)
Testing
OUT_
Ev
on
*
LED
7347
CB-TEST canceled due to CB
already OPEN (CB-TSTstop
OPEN)
Testing
OUT_
Ev
on
*
LED
7348
CB-TEST canceled due to CB
was NOT READY (CB-TSTstop
NOTr)
Testing
OUT_
Ev
on
*
LED
7349
CB-TEST canceled due to CB
stayed CLOSED (CB-TSTstop
CLOS)
Testing
OUT_
Ev
on
*
LED
7350
CB-TEST was succesful (CB-
TST .OK.)
Testing
OUT_
Ev
on
*
LED
13800
di/dt function is active in Zone Z2
(Z2di/dt ACTIVE)
Distance prot.
OUT
on
off
*
*
LED
BO
13801
du/dt function is active in Zone Z2
(Z2du/dt ACTIVE)
Distance prot.
OUT
on
off
*
*
LED
BO
13802
di/dt function is active in Zone Z3
(Z3di/dt ACTIVE)
Distance prot.
OUT
on
off
*
*
LED
BO
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
Ev
ent Log
O
N
/O
FF
T
rip (
Faul
t)
Log On/
O
ff
G
round
Fault Log ON/
O
FF
M
a
rk
e
d
i
n
O
s
ci
ll.
Re
c
o
rd
LED
B
ina
ry
I
n
pu
t
Function
Key
Rela
y
Chatte
r Suppr
e
ssion
Ty
p
e
In
form
ati
on Nu
mbe
r
Dat
a
Un
it
Ge
ne
ra
l Int
e
rro
ga
ti
on
www
. ElectricalPartManuals
. com