21.3
Ctrl-E profiles
21.3.1
Using the energy-saving profile
In the "Ctrl-E profiles" window, you can display all of the defined energy-saving profiles. Here,
you have the option of directly activating or inhibiting a required energy-saving profile, or re-
enabling profiles.
SINUMERIK Ctrl-Energy energy-saving profiles
Display
Meaning
Energy-saving profile
All energy-saving profiles are listed.
active in [min]
The remaining time until the defined profile is reached is displayed.
Note
Disable all energy-saving profiles
For example, in order not to disturb the machine while measurements are being made, select
"Disable all".
Once the pre-warning time of a profile has been reached, an alarm window that shows the
remaining time is displayed. Once the energy-saving mode has been reached, then an
appropriate message is displayed in the alarm line.
Predefined energy-saving profiles
Energy-saving profile
Meaning
Simple energy-saving mode
(machine standby)
Machine units that are not required are either throttled or shut down.
When required, the machine is immediately ready to operate again.
Full energy-saving mode (NC
standby)
Machine units that are not required are either throttled or shut down.
Wait times are incurred at the transition into the ready to operate state.
Maximum energy-saving
mode (auto shut-off)
The machine is completely switched-off.
Longer wait times are incurred at the transition into the ready to operate
state.
Machine manufacturer
The selection and function of the displayed energy-saving profiles can differ.
Please observe the information provided by the machine manufacturer.
Ctrl-Energy
21.3 Ctrl-E profiles
Turning
Operating Manual, 06/2019, A5E44903486B AB
921