4.7
Settings for the measurement result log
Make the following settings in the "Settings for measurement log" window:
● Log format
– Text format
The log in the text format is based on the display of the measurement results on the
screen.
– Tabular format
When selecting the tabular format, the measurement results are saved so that the data
can be imported into a spreadsheet program (e.g. Microsoft Excel). This allows the
measurement result logs to be statistically processed.
● Log data
– new
The log of the actual measurement is created under the specified name. Existing logs
with the same name are overwritten.
– attach
The log created is attached to the previous log.
● Where the log is saved
The log created is saved in a specified directory.
Procedure
1.
Select the "Machine" operating area.
2.
Press the <JOG> key.
3.
Press the menu forward key and the "Settings" softkey.
4.
Press the "Measurement log" softkey.
The "Settings for measurement log" window is opened.
5.
Position the cursor to the log format field and select the required entry.
6.
Position the cursor to the log data field and select the required entry.
7.
Position the cursor to the log archive field and press the softkey "Select
directory".
8.
Navigate to the desired directory for the log archive.
9.
Press the "OK" softkey and enter the name for the log file.
Setting up the machine
4.7 Settings for the measurement result log
Turning
Operating Manual, 06/2019, A5E44903486B AB
115