7.8
Program control during the simulation
7.8.1
Changing the feedrate
You have the capability of changing the feedrate at any time during the simulation.
You track the changes in the status bar.
Note
If you are working with the "Simultaneous recording" function, you use the rotary switch
(override) on the control panel.
Procedure
1.
Simulation is started.
2.
Press the "Program control" softkey.
3.
Press the "Ov" or "Override -" softkey to increase or decrease the
feedrate by 5%, respectively.
- OR -
Press the "100% override" softkey to set the feedrate to 100%.
- OR -
Press the "<<" softkey to return to the main screen and perform the
simulation with changed feedrate.
Toggling between "Ov" and "Override -"
Simultaneously press the <Ctrl> and <cursor down> or <cursor up> keys to
toggle between the "Ov" and "Override -" softkeys.
Selecting the maximum feedrate
Press the <Ctrl> and <M> keys simultaneously to select the maximum fee‐
drate of 120%.
Simulating machining
7.8 Program control during the simulation
Turning
252
Operating Manual, 06/2019, A5E44903486B AB