Procedure
1.
Select the "JOG" mode in the "Machine" operating area.
2.
Press the "Set WO" softkey.
- OR -
Press the ">>", "REL act. vals" and "Set REL" softkeys to set position
values in the relative coordinate system.
3.
Enter the new required position value for Z, X or Y directly in the actual
value display (you can toggle between the axes with the cursor keys) and
press the <INPUT> key to confirm the entries.
- OR -
Press softkey "Z=0", "X=0" or "Y=0" (if there is a Y axis), to set the re‐
quired position to zero.
Resetting the actual value
Press the "Delete active WO" softkey.
The offset is deleted permanently.
NOTICE
Irreversible active zero offset
The current active zero offset is irreversibly deleted by this action.
Setting up the machine
4.4 Settings for the machine
Turning
104
Operating Manual, 06/2019, A5E44903486B AB