Mounting the transmitter
1. Remove locking cap from mounting bracket.
2. Mount transmitter on mounting bracket taking care that the flutes on the mating faces are
correctly engaged.
3. Firmly tighten locking cap on mounting bracket (torque: 25 Nm).
Turning the transmitter
In a remote configuration, the transmitter can be turned horizontally and tilted vertically.
Horizontal rotation
1. Unscrew cap from lock screw.
2. Loosen lock screw at transmitter pedestal using 5 mm Allen key.
3. Carefully rotate transmitter into desired position.
r
r
4. Firmly tighten lock screw (torque: 10 Nm).
5. Replace cap onto lock screw (torque: 10 Nm).
Installing/mounting
4.2 Installation instructions
MASS 2100 & FC300 (FCT030)
52
Operating Instructions, 06/2017, A5E39789040-AA