HMI menu ID Parameter
Description
Default value
[unit]
Value range
Access
level
2.2.5.7
Empty Tube Detection
"Activate empty tube detection.
""On"": Density value below
empty tube limit triggers alarm.
All flow rate values are forced to
zero %.
Off
● Off
● On
User
2.2.5.8
Empty Tube Limit
"Set density value for empty
tube limit.
Density value below limit trig‐
gers an alarm."
500
[kg/m³]
-14000.0 to
14000.0
User
Table B-5
Medium temperature
HMI menu ID Parameter
Description
Default value
[unit]
Value range
Access
level
2.2.6.1
Units
Select unit for displayed temper‐
ature. Unit is not applied at com‐
munication interface.
°C
● °C (degrees
Celcius)
● °F (degrees
Fahrenheit)
● °R degrees
Rankine
● K (kelvins)
User
2.2.6.2
Decimal places
Define the decimal point for the
process value displayed in the
Local User Interface.
2
● Auto
● No decimal
place
● 1
● 2
● 3
● 4
● 5
● 6
User
2.2.6.3
Alarm and warning limits
2.2.6.3.1
Upper Limit Alarm
Set upper alarm limit. Alarm is
triggered if temperature value is
above the limit.
200
[°C]
-50 to 200
User
2.2.6.3.2
Upper Limit Warning
Set upper warning limit. Warning
is triggered if temperature value
is above the limit.
200
[°C]
-50 to 200
User
2.2.6.3.3
Lower Limit Warning
Set lower warning limit. Warning
is triggered if temperature value
is below the limit.
-50
[°C]
-50 to 200
User
Default settings
B.3 Standard volume flow
MASS 2100 & FC300 (FCT030)
Operating Instructions, 06/2017, A5E39789040-AA
279