
Table 11-18 System design
Description
Specification
Measuring principle
Coriolis
System architecture
Compact configuration
Remote configuration
Device design
Table 11-19 Transmitter design
Description
Specification
Dimension and weight
See "Dimensions and weight"
Design
Compact or remote
Material
Aluminum with corrosion-resistant coating
Ingress protection
IP67/NEMA 4X to EN/IEC 60529 (1 mH
2
O for 30
min.)
Mechanical load
18 to 1000 Hz random, 3.17 g RMS, in all direc‐
tions, to IEC 68-2-36
Torques
Table 11-20 Installation torques
Description
Torque (Nm)
Pressure guard fittings
G 1/4 inch
80
Wall bracket screws
10
Transmitter to wall bracket
25
Transmitter pedestal lock screw
Compact version:
10
Remote version:
6
Pedestal lock screw cap
10
Cable gland to housing (Siemens supplied, metric)
10
Note
NPT glands
When using NPT glands, the user must take care to use the supplied NPT thread adaptors.
Technical data
11.6 Construction
MASS 2100 & FC300 (FCT030)
Operating Instructions, 06/2017, A5E39789040-AA
231