Parameters
Introduction to Parameters
1-10
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Data type
The data types available are shown in the table below.
The information of the data types for binector and connector inputs can be com-
posed of two specifications (discreated by a slash):
Depending on the data type of the BICO input parameter (signal sink) and BICO
output parameter (signal source) the following combinations are possible when
creating BICO interconnections:
Table 1-1
Available data types
Notation
Meaning
Unsigned8 (U8)
8-bit unsigned
Unsigned16 (U16)
16-bit unsigned
Unsigned32 (U32)
32-bit unsigned
Integer16 (I16)
16-bit integer
Integer32 (I32)
32-bit integer
FloatingPoint32 (Float)
32-bit floating point number
First specification:
data type of the parameter
Second specification:
data type of the signal source preferably to be con-
nected (binector or connector output)
Table 1-2
Possible combinations of BICO interconnections
BICO input parameter
CI parameter
BI parameter
BICO output parameter
Unsigned32 /
Integer16
Unsigned32 /
Integer32
Unsigned32 /
FloatingPoint32
Unsigned32 /
Binary
CO: Unsigned8
x
x
–
–
CO: Unsigned16
x
x
–
–
CO: Unsigned32
x
x
–
–
CO: Integer16
x
x
r2050
–
CO: Integer32
x
x
–
–
CO: FloatingPoint32
x
x
x
–
BO: Unsigned8
–
–
–
x
BO: Unsigned16
–
–
–
x
BO: Unsigned32
–
–
–
x
BO: Integer16
–
–
–
x
BO: Integer32
–
–
–
x
BO: FloatingPoint32
–
–
–
–
Legend:
x: BICO interconnection permitted
–: BICO interconnection not permitted