List of Parameters
Parameters
1-327
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Sets the mapping parameters for CANopen Transmit Process Data Object 7 (TPDO 7).
Index:
[0] = Mapped object 1
[1] = Mapped object 2
[2] = Mapped object 3
[3] = Mapped object 4
Note:
Corresponds to the CANopen object 1A06 hex + 40 hex * x (x: Drive number 0 ... 7).
The parameter can only be written online when the associated COB ID in p872x is set as invalid.
Description:
Sets the mapping parameters for CANopen Transmit Process Data Object 8 (TPDO 8).
Index:
[0] = Mapped object 1
[1] = Mapped object 2
[2] = Mapped object 3
[3] = Mapped object 4
Note:
Corresponds to the CANopen object 1A07 hex + 40 hex * x (x: Drive number 0 ... 7).
The parameter can only be written online when the associated COB ID in p872x is set as invalid.
Description:
Acknowledges the setting of the Predefined Connection Sets (p8744).
Value:
0:
Inactive
1:
Acknowledge configuration
Dependency:
Refer to: p8744
Description:
Selector switch for the PDO mapping.
Sets the mapping for download or in the online mode after acknowledging with p8741.
Value:
1:
Predefined Connection Set
2:
Free PDO Mapping
p8736[0...3]
CAN Transmit Mapping for TPDO 7 / Mapping TPDO 7
CU230P-2 CAN
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(3), T
Scaling:
-
Data set:
-
Min Max Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
p8737[0...3]
CAN Transmit Mapping for TPDO 8 / Mapping TPDO 8
CU230P-2 CAN
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(3), T
Scaling:
-
Data set:
-
Min Max Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
p8741
CAN PDO configuration acknowledgement / PDO config ackn
CU230P-2 CAN
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 1 0
p8744
CAN PDO mapping configuration / PDO Mapping conf.
CU230P-2 CAN
Access level:
2
Calculated:
-
Data type:
Integer16
Can be changed:
C, T
Scaling:
-
Data set:
-
Min Max Factory
setting
1 2 2