List of Parameters
Parameters
1-361
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Setting parameter for the run sequence of instance ADD 1 within the run-time group set in p20100.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source of minuend X1 and subtrahend X2 of instance SUB 0 of the subtractor.
Index:
[0] = Minuend X1
[1] = Subtrahend X2
Description:
Display parameter for the difference Y = X1-X2 of instance SUB 0 of the subtractor.
Description:
Setting parameter for the run-time group in which instance SUB 0 of the subtractor is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance SUB 0 within the run-time group set in p20104.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source of minuend X1 and subtrahend X2 of instance SUB 1 of the subtractor.
Index:
[0] = Minuend X1
[1] = Subtrahend X2
p20101
ADD 1 run sequence / ADD 1 RunSeq
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 32000
220
p20102[0...1]
CI: SUB 0 inputs / SUB 0 inputs
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Data set:
-
Min Max Factory
setting
- - 0
r20103
CO: SUB 0 difference Y / SUB 0 difference Y
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Unit:
-
Scaling:
PERCENT
Data set:
-
p20104
SUB 0 run-time group / SUB 0 RTG
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
5 9999
9999
p20105
SUB 0 run sequence / SUB 0 RunSeq
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 32000
240
p20106[0...1]
CI: SUB 1 inputs / SUB 1 inputs
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Data set:
-
Min Max Factory
setting
- - 0