List of Parameters
Parameters
1-333
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Displays the parameters whose parameter would have to be changed during a units changeover.
Description:
Sets the signal source (BO/CO parameter, BICO coded) to search in the signal sinks.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the num-
ber (r9485) and the first index (r9486).
Dependency:
Refer to: r9485, r9486
Description:
Displays the number of BICO interconnections to the signal sink being searched for.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the num-
ber (r9485) and the first index (r9486).
Dependency:
Refer to: p9484, r9486
Description:
Displays the first index of the signal source being searched for.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the num-
ber (r9485) and the first index (r9486).
Dependency:
Refer to: p9484, r9485
Description:
Displays the directory and name of the file whose status as shipped from the factory was identified as impermissi-
ble.
Dependency:
Refer to: r9926
Refer to: A01016
Note:
The directory and name of the file is displayed in the ASCII code.
Description:
Displays the status when the firmware is checked when the system is booted.
0: Firmware not yet checked.
1: Check running.
2: Check successfully completed.
3: Check indicates an error.
Dependency:
Refer to: r9925
Refer to: A01016
r9451[0...29]
Units changeover adapted parameters / Unit_chngov par
Access level:
4
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
p9484
BICO interconnections search signal source / BICO S_src srch
Access level:
4
Calculated:
-
Data type:
Unsigned32
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 4294967295
0
r9485
BICO interconnections signal source search count / BICO S_src srchQty
Access level:
4
Calculated:
-
Data type:
Unsigned16
Unit:
-
Scaling:
-
Data set:
-
r9486
BICO interconnections signal source search first index / BICO S_src srchIdx
Access level:
4
Calculated:
-
Data type:
Unsigned16
Unit:
-
Scaling:
-
Data set:
-
r9925[0...99]
Firmware file incorrect / FW file incorr
Access level:
3
Calculated:
-
Data type:
Unsigned8
Unit:
-
Scaling:
-
Data set:
-
r9926
Firmware check status / FW check status
Access level:
3
Calculated:
-
Data type:
Unsigned8
Unit:
-
Scaling:
-
Data set:
-
Summary of Contents for CU230P-2 CAN
Page 1: ...s SINAMICS G120 Control Units CU230P 2 Parameter Manual 11 2009 SINAMICS ...
Page 2: ......
Page 667: ......