Parameters
List of Parameters
1-336
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Sets the signal source to switch in/switch out the free technology controller 0.
1 signal: The technology controller is switched in.
0 signal: The technology controller is switched out.
Description:
Sets the sampling time for the free technology controller 0.
Value:
0:
Reserved
1:
128 ms
2:
256 ms
3:
512 ms
4:
1024 ms
Description:
Displays the status word of the free technology controller 0.
Description:
Sets the signal source for the setpoint of the free technology controller 0.
Description:
Sets the ramp-up time for the free technology controller 0.
Dependency:
Refer to: p11058
Note:
The ramp-up time is referred to 100 %.
p11000
BI: Free tec_ctrl 0 enable / Ftec0 enab
Access level:
2
Calculated:
-
Data type:
U32 / Binary
Can be changed:
U, T
Scaling:
-
Data set:
-
Min Max Factory
setting
- - 0
p11028
Free tec_ctrl 0 sampling time / Ftec0 t_samp
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 4 2
r11049.0...11
CO/BO: Free tec_ctrl 0 status word / Ftec0 stat_word
Access level:
3
Calculated:
-
Data type:
Unsigned32
Unit:
-
Scaling:
-
Data set:
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Deactivated
Yes
No
-
01
Limited
Yes
No
-
08
Actual value at the minimum
Yes
No
-
09
Actual value at the maximum
Yes
No
-
10
Output at the minimum
Yes
No
-
11
Output at the maximum
Yes
No
-
p11053
CI: Free tec_ctrl 0 setpoint signal source / Ftec0 setp s_s
Access level:
2
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Data set:
-
Min Max Factory
setting
- - 0
p11057
Free tec_ctrl 0 setpoint ramp-up time / Ftec0 setp t_r-up
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Data set:
-
Min Max Factory
setting
0.00 [s]
650.00 [s]
1.00 [s]