Parameters
Command and Drive Data Sets – Overview
1-412
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
p1123[0...n]
Ramp-function generator minimum ramp-up time / RFG t_RU min
p1127[0...n]
Ramp-function generator minimum ramp-down time / RFG t_RD min
p1130[0...n]
Ramp-function generator initial rounding-off time / RFG t_start_round
p1131[0...n]
Ramp-function generator final rounding-off time / RFG t_end_delay
p1134[0...n]
Ramp-function generator rounding-off type / RFG round-off type
p1135[0...n]
OFF3 ramp-down time / OFF3 t_RD
p1136[0...n]
OFF3 initial rounding-off time / RFGOFF3 t_strt_rnd
p1137[0...n]
OFF3 final rounding-off time / RFG OFF3 t_end_del
p1145[0...n]
Ramp-function generator tracking intensity. / RFG track intens
p1148[0...n]
Ramp-function gen., tolerance for ramp-up and ramp-down active / RFG tol HL/RL act
p1200[0...n]
FlyRest oper mode / FlyRest op_mode
p1202[0...n]
FlyRest srch curr / FlyRest I_srch
p1203[0...n]
Flying restart search rate factor / FlyRst v_Srch Fact
p1226[0...n]
Threshold for zero speed detection / n_standst n_thresh
p1240[0...n]
Vdc controller or Vdc monitoring configuration (vector control) / Vdc_ctr config vec
p1243[0...n]
Vdc_max controller dynamic factor / Vdc_max dyn_factor
p1245[0...n]
Vdc_min controller switch-in level (kinetic buffering) / Vdc_min on_level
p1247[0...n]
Vdc_min controller dynamic factor (kinetic buffering) / Vdc_min dyn_factor
p1249[0...n]
Vdc_max controller speed threshold / Vdc_max n_thresh
p1250[0...n]
Vdc controller proportional gain / Vdc_ctrl Kp
p1251[0...n]
Vdc controller integral time / Vdc_ctrl Tn
p1252[0...n]
Vdc controller rate time / Vdc_ctrl t_rate
p1255[0...n]
Vdc_min controller time threshold / Vdc_min t_thresh
p1256[0...n]
Vdc_min controller response (kinetic buffering) / Vdc_min response
p1257[0...n]
Vdc_min controller speed threshold / Vdc_min n_thresh
p1262[0...n]
Bypass dead time / Bypass t_dead
p1280[0...n]
Vdc controller or Vdc monitoring configuration (V/f) / Vdc_ctr config V/f
p1283[0...n]
Vdc_max controller dynamic factor (V/f) / Vdc_max dyn_factor
p1285[0...n]
Vdc_min controller switch-in level (kinetic buffering) (V/f) / Vdc_min on_level
p1287[0...n]
Vdc_min controller dynamic factor (kinetic buffering) (V/f) / Vdc_min dyn_factor
p1288[0...n]
Vdc_max controller feedback coupling factor ramp-fct. gen. (V/f) / Vdc_max factor RFG
p1290[0...n]
Vdc controller proportional gain (V/f) / Vdc_ctrl Kp
p1291[0...n]
Vdc controller integral time (V/f) / Vdc_ctrl Tn
p1292[0...n]
Vdc controller rate time (V/f) / Vdc_ctrl t_rate
p1293[0...n]
Vdc min controller output limit (V/f) / Vdc_min outp_lim
p1295[0...n]
Vdc_min controller time threshold (V/f) / Vdc_min t_thresh
p1296[0...n]
Vdc_min controller response (kinetic buffering) (V/f / Vdc_min response
p1297[0...n]
Vdc_min controller speed threshold (V/f) / Vdc_min n_thresh
p1300[0...n]
Open-loop/closed-loop control operating mode / Op/cl-lp ctrl_mode
p1310[0...n]
Voltage boost permanent / V_boost perm
p1311[0...n]
Voltage boost at acceleration / V_boost accelerate
p1312[0...n]
Voltage boost when starting / V_boost starting
p1320[0...n]
V/f control programmable characteristic frequency 1 / Uf char f1
p1321[0...n]
V/f control programmable characteristic voltage 1 / Vf char U1
p1322[0...n]
V/f control programmable characteristic frequency 2 / Vf char f2
p1323[0...n]
V/f control programmable characteristic voltage 2 / Vf char U2
p1324[0...n]
V/f control programmable characteristic frequency 3 / Vf char f3
p1325[0...n]
V/f control programmable characteristic voltage 3 / Vf char U3
p1326[0...n]
V/f control programmable characteristic frequency 4 / Vf char f4
p1327[0...n]
V/f control programmable characteristic voltage 4 / Vf char U4
p1333[0...n]
V/f control FCC starting frequency / V/f FCC f_start
p1334[0...n]
V/f control slip compensation starting frequency / Slip comp start
p1335[0...n]
Slip compensation, scaling / Slip comp scal
Summary of Contents for CU230P-2 CAN
Page 1: ...s SINAMICS G120 Control Units CU230P 2 Parameter Manual 11 2009 SINAMICS ...
Page 2: ......
Page 667: ......