List of Parameters
Parameters
1-201
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Displays the integral component of the Isq current controller (torque/force-generating current, PI controller).
Description:
Displays the actual output of the Isd current controller (flux-generating current, PI controller).
The value contains the proportional and integral components of the PI controller.
Description:
Displays the integral component of the Isd current controller (flux-generating current, PI controller).
Description:
Displays the limit value for the integral component of the Isd current controller.
Description:
Sets the scaling of the quadrature arm decoupling
Note:
This parameter is ineffective for encoderless vector control. In this case, p1727 is always used. If p1726 is set to 0,
then the quadrature de-coupling is deactivated. The integral component of the Isd current controller remains effec-
tive in the complete speed control range.
For the closed-loop control of synchronous motors, this parameter is used to scale the current controller de-cou-
pling.
Description:
Sets the scaling of quadrature arm decoupling when the voltage limit is reached.
Description:
Displays the actual output of the quadrature channel de-coupling for the d axis.
Description:
Displays the actual output of the quadrature channel de-coupling for the q axis.
r1719
Isq controller integral component / Isq_ctrl I_comp
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[Vrms]
Scaling:
p2001
Data set:
-
r1723
CO: Isd controller output / Isd_ctrl outp
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[Vrms]
Scaling:
p2001
Data set:
-
r1724
Isd controller integral component / Isd_ctrl I_comp
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[Vrms]
Scaling:
p2001
Data set:
-
r1725
Isd controller integral component limit / Isd_ctrl I_limit
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[Vrms]
Scaling:
p2001
Data set:
-
p1726[0...n]
Quadrature arm decoupling, scaling / Transv_decpl scal
Access level:
4
Calculated:
p0340 = 1
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Data set:
DDS, p0180
Min Max Factory
setting
0.0 [%]
200.0 [%]
75.0 [%]
p1727[0...n]
Quadrature arm decoupling at voltage limit scaling / TrnsvDecplVmaxScal
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Data set:
DDS, p0180
Min Max Factory
setting
0.0 [%]
200.0 [%]
50.0 [%]
r1728
De-coupling voltage, in-line axis / V_dir-axis_decoupl
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[Vrms]
Scaling:
p2001
Data set:
-
r1729
De-coupling voltage, quadrature axis / V_quad_decoupl
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Unit:
[Vrms]
Scaling:
p2001
Data set:
-
Summary of Contents for CU230P-2 CAN