List of Parameters
Parameters
1-363
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Setting parameter for the run sequence of instance MUL 0 within the run-time group set in p20112.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source of the factors X0, X1, X2, X3 of instance MUL 1 of the multiplier.
Index:
[0] = Factor X0
[1] = Factor X1
[2] = Factor X2
[3] = Factor X3
Description:
Display parameter for the product Y = X0 * X1 * X2 * X3 of instance MUL 1 of the multiplier.
Description:
Setting parameter for the run-time group in which instance MUL 1 of the multiplier is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance MUL 1 within the run-time group set in p20116.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source of dividend X1 and divisor X2 of instance DIV 0 of the divider.
Index:
[0] = Dividend X1
[1] = Divisor X2
p20113
MUL 0 run sequence / MUL 0 RunSeq
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 32000
270
p20114[0...3]
CI: MUL 1 inputs / MUL 1 inputs
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Data set:
-
Min Max Factory
setting
- - 0
r20115
CO: MUL 1 product Y / MUL 1 product Y
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Unit:
-
Scaling:
PERCENT
Data set:
-
p20116
MUL 1 run-time group / MUL 1 RTG
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
5 9999
9999
p20117
MUL 1 run sequence / MUL 1 RunSeq
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Data set:
-
Min Max Factory
setting
0 32000
280
p20118[0...1]
CI: DIV 0 inputs / DIV 0 inputs
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Data set:
-
Min Max Factory
setting
- - 0