List of Parameters
Parameters
1-101
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Description:
Sets the simulation mode for digital inputs.
Dependency:
The setpoint for the input signals is specified using p0796.
Refer to: p0796
Note:
This parameter is not saved when data is backed up (p0971).
DI: Digital input
AI: Analog Input
T: Terminal
Description:
Sets the setpoint for the input signals in the digital input simulation mode.
Dependency:
The simulation of a digital input is selected using p0795.
Refer to: p0795
Note:
This parameter is not saved when data is backed up (p0971).
DI: Digital input
AI: Analog Input
T: Terminal
p0795
CU digital inputs simulation mode / CU DI simulation
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Data set:
-
Min Max Factory
setting
- - 0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DI 0 (T. 5)
Simulation
Terminal eval.
-
01
DI 1 (T. 6)
Simulation
Terminal eval.
-
02
DI 2 (T. 7)
Simulation
Terminal eval.
-
03
DI 3 (T. 8)
Simulation
Terminal eval.
-
04
DI 4 (T. 16)
Simulation
Terminal eval.
-
05
DI 5 (T. 17)
Simulation
Terminal eval.
-
11
DI 11 (T. 3, 4) AI 0
Simulation
Terminal eval.
-
12
DI 12 (T.10, 11) AI 1
Simulation
Terminal eval.
-
p0796
CU digital inputs simulation mode setpoint / CU DI simul setp
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Data set:
-
Min Max Factory
setting
- - 0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DI 0 (T. 5)
High
Low
-
01
DI 1 (T. 6)
High
Low
-
02
DI 2 (T. 7)
High
Low
-
03
DI 3 (T. 8)
High
Low
-
04
DI 4 (T. 16)
High
Low
-
05
DI 5 (T. 17)
High
Low
-
11
DI 11 (T. 3, 4) AI 0
High
Low
-
12
DI 12 (T. 10, 11) AI 1
High
Low
-
Summary of Contents for CU230P-2 CAN
Page 1: ...s SINAMICS G120 Control Units CU230P 2 Parameter Manual 11 2009 SINAMICS ...
Page 2: ......
Page 667: ......