background image

YASKAWA AC Drive V/J1000

External Heatsink Attachment

Option Manual

MANUAL NO.   EZZ020568

To properly use the product, read this manual thoroughly and retain 

for easy reference, inspection, and maintenance. Ensure the end user 

receives this manual.

Type: CIMR-J

Type: CIMR-V                                      

Summary of Contents for J1000 CIMR-JC series

Page 1: ...l Heatsink Attachment Option Manual MANUAL NO EZZ020568 To properly use the product read this manual thoroughly and retain for easy reference inspection and maintenance Ensure the end user receives this manual Type CIMR J Type CIMR V ...

Page 2: ...therwise without the prior written permission of Yaskawa No patent liability is assumed with respect to the use of the information contained herein Moreover because Yaskawa is constantly striving to improve its high quality products the information contained in this manual is subject to change without notice Every precaution has been taken in the preparation of this manual Yaskawa assumes no respo...

Page 3: ...T THIS OPTION 7 4 EXTERNAL HEATSINK OPTION INSTALLATION PROCEDURE 9 5 INSTALLATION PROCEDURE BY DRIVE MODEL 12 6 EXTERNAL HEATSINK OPTION PART NUMBERS BY DRIVE MODEL 21 7 REVISION HISTORY 23 YASKAWA V1000 J1000 AC Drive External Heatsink Kit Option Manual EZZ020568 3 ...

Page 4: ...s warranty only as to the quality of its products in conforming to standards and specifications published in the Yaskawa manual NO OTHER WARRANTY EXPRESS OR IMPLIED IS OFFERED Yaskawa assumes no liability for any personal injury property damage losses or claims arising from misapplication of its products u Applicable Documentation The following manuals are available for the J1000 and V1000 Drives ...

Page 5: ...les office and provide the manual number shown on the front cover Order a replacement from your Yaskawa representative or the nearest Yaskawa sales office if nameplate becomes worn or damaged WARNING Read and understand this manual before installing operating or servicing this drive The drive must be installed according to this manual and local codes The following conventions are used to indicate ...

Page 6: ...ct Do not touch any terminals before the capacitors have fully discharged Failure to comply could result in death or serious injury Before installing the option disconnect all power to the drive The internal capacitor remains charged even after the power supply is turned off The charge indicator LED will extinguish when the DC bus voltage is below 50 Vdc To prevent electric shock wait at least fiv...

Page 7: ...ng an enclosure panel install a cooling fan or air conditioner in the area to ensure that the air temperature inside the enclosure does not exceed the specified levels Do not allow ice to develop on the drive Humidity 95 RH or less and free of condensation Storage Temperature 20 C to 60 C 4 F to 104 F Surrounding Area Install the drive in an area free from oil mist and dust metal shavings oil wate...

Page 8: ... s2 Orientation Install the drive vertically to maintain maximum cooling effects NOTICE Prevent foreign matter such as metal shavings and wire clippings from falling into the drive during installation Failure to comply could result in damage to the drive Place a temporary cover over the top of the drive during installation Remove the temporary cover before drive start up as the cover will reduce v...

Page 9: ...alled Table 3 Drive Models and Dimensions Series Drive Model Number Reference J1000 CIMR JoBo0001 to 0010 Figure 1 CIMR Jo2o0001 to 0020 CIMR Jo4o0001 to 0011 V1000 CIMR VoBo0001 to 0018 CIMR Vo2o0001 to 0020 CIMR Vo4o0001 to 0011 CIMR Vo2o0030 to 0069 Figure 2 CIMR Vo4o0018 to 0038 4 External Heatsink Option Installation Procedure YASKAWA V1000 J1000 AC Drive External Heatsink Kit Option Manual E...

Page 10: ...2 7 56 2 2 160 6 3 148 5 8 69 5 2 7 12 0 5 30 1 2 2 0 1 o2o0004 68 2 7 56 2 2 160 6 3 148 5 8 69 5 2 7 42 1 7 50 2 0 2 0 1 o2o0006 68 2 7 56 2 2 160 6 3 148 5 8 69 5 2 7 62 2 4 70 2 8 2 0 1 o2o0008 o2o0010 108 4 3 96 3 8 158 6 2 144 5 7 71 2 8 58 2 3 70 2 8 4 0 2 o2o0012 108 4 3 96 3 8 158 6 2 144 5 7 79 5 3 1 58 2 3 70 2 8 4 0 2 o2o0018 o2o0020 140 5 5 128 5 0 158 6 2 144 5 7 78 3 0 65 2 5 70 2 8...

Page 11: ...53 4 2 1 60 2 4 5 0 2 o2o0056 198 7 8 160 6 3 322 12 7 308 12 1 89 6 3 4 73 4 2 9 80 3 1 5 0 2 o2o0069 241 9 5 192 7 5 380 15 0 362 14 2 110 6 4 4 76 4 3 0 85 3 3 5 0 2 o4o0018 158 6 2 122 4 8 286 11 3 272 10 7 86 6 3 4 53 4 2 1 60 2 4 5 0 2 o4o0023 158 6 2 122 4 8 286 11 3 272 10 7 86 6 3 4 53 4 2 1 60 2 4 5 0 2 o4o0031 198 7 8 160 6 3 322 12 7 308 12 1 89 6 3 5 53 4 2 1 60 2 4 5 0 2 o4o0038 198 ...

Page 12: ...e 5 Figure 6 oBo0018 3 15 Figure 5 o2o0001 o2o0002 1 13 Figure 3 o2o0004 o2o0006 o2o0008 o2o0010 3 4 15 15 Figure 5 Figure 6 o2o0012 o2o0018 o2o0020 o4o0001 2 14 Figure 4 o4o0002 3 15 Figure 5 o4o0004 o4o0005 o4o0007 o4o0009 3 4 15 15 Figure 5 Figure 6 o4o0011 o2o0030 5 18 Figure 8 o2o0040 o2o0056 o2o0069 o4o0018 o4o0023 o4o0031 o4o0038 5 Installation Procedure by Drive Model 12 YASKAWA V1000 J100...

Page 13: ... pan head screws 3 Mount Attachment B 2 units to Attachment A with the associated M4 10 pan head screws as shown in Figure 3 4 Reattach the front cover according to the drive instruction manual Attachment B Attachment A Attachment B M4x13 Pan head Screws x4 Figure 3 Procedure 1 Diagram Example Model CIMR Vo2o0001 5 Installation Procedure by Drive Model YASKAWA V1000 J1000 AC Drive External Heatsin...

Page 14: ...nits to Attachment A with the associated M4 10 pan head screws as shown in Figure 4 4 Reattach the front cover according to the drive instruction manual Attachment B Attachment A Attachment A Attachment B M4 x 10 Pan head Screws x4 M4 x 10 Pan head Screws x2 Figure 4 Procedure 2 Diagram Example Model CIMR Vo4o0001 5 Installation Procedure by Drive Model 14 YASKAWA V1000 J1000 AC Drive External Hea...

Page 15: ... Figure 5 Procedure 3 Diagram Example Model CIMR Vo2o0010 n Procedure 4 Enclosure IP20 1 Mount the Convective Back Plate to the mounting holes on underside of the heatsink using M4 10 pan head screws M4 x 10 Pan head Screw Convective back plate Figure 6 Procedure 4 Diagram Example Model CIMR Vo2o0010 5 Installation Procedure by Drive Model YASKAWA V1000 J1000 AC Drive External Heatsink Kit Option ...

Page 16: ... 4 128 5 0 144 128 146 5 7 5 0 80 3 1 106 4 2 96 144 5 7 5 7 128 146 142 5 6 168 6 6 158 6 2 144 32 1 2 30 5 30 5 56 27 27 27 27 27 27 27 1 1 1 1 27 27 27 27 27 1 1 1 1 1 1 1 1 4 M4 Tap 2 n 5 holes 4 M4 Tap 2 n 5 holes 4 M4 Tap 2 n 5 holes 4 M4 Tap 2 n 5 holes 1 3 32 1 3 5 4 5 7 2 2 2 7 1 1 1 1 5 0 1 1 1 1 1 1 1 1 3 8 5 0 5 7 Fig A Fig B Fig C Fig D 5 Installation Procedure by Drive Model 16 YASKA...

Page 17: ...unting panel surface or apply sealant to fill the gap Refer to Figure 7 for sealant placement Refer to Figure A B C or D for gasket dimensions for your specific model Gasket type CR Series or EPDM Series made of foam rubber approximately 2 mm in thick Sealant Sealant Figure 7 Sealant Placement 5 Installation Procedure by Drive Model YASKAWA V1000 J1000 AC Drive External Heatsink Kit Option Manual ...

Page 18: ...atsink using M5 x12 pan head screws as shown in Figure 4 Table 7 Installation Fasteners by Model for Figure 4 Drive Model Installation Fasteners CIMR Vo2o0030 to 0056 CIMR Vo4o0018 to 0038 M5 x 12 Pan head Screws x4 CIMR Vo2o0069 M6 x 14 Pan head Screws x4 Attachment 1 Attachment 2 M5 x 12 Pan head Screws x2 screw size varies by model M5 x 12 Pan head Screws x2 screw size varies by model Figure 9 ...

Page 19: ...M4 x10 pan head screws Attachment 3 M4 x 10 Pan head Screws x2 Figure 10 Attachment 3 4 Complete the assembly a Install the terminal cover Figure 11 Completed Assembly 5 Installation Procedure by Drive Model YASKAWA V1000 J1000 AC Drive External Heatsink Kit Option Manual EZZ020568 19 ...

Page 20: ...e Drive Model CIMR Dimensions mm in W H W1 W2 W3 H1 H2 H3 A B d Vo2o0030 158 6 2 286 11 3 122 4 8 9 0 4 9 0 4 272 10 7 60 2 4 7 0 3 140 5 5 255 10 0 5 0 2 Vo2o0040 158 6 2 286 11 3 122 4 8 9 0 4 9 0 4 272 10 7 60 2 4 7 0 3 140 5 5 255 10 0 5 0 2 Vo2o0056 198 7 8 322 12 7 160 6 3 10 0 4 9 0 4 308 12 1 80 3 1 7 0 3 180 7 0 287 11 2 5 0 2 Vo2o0069 241 9 5 380 15 0 192 7 5 14 0 5 10 5 0 4 362 14 2 85 ...

Page 21: ...rews 5 Figure B o2o0018 o2o0020 100 034 080 EZZ020568E SPAT35096 A 2 SPAT35098 1 M4 10 Pan head Screws 5 Figure C o4o0001 100 034 078 EZZ020568L SPAT45974 1 2 SPAT45975 1 2 M4 10 Pan head Screws 4 Figure B o4o0002 o4o0004 100 036 418 EZZ020568C SPAT35095 A 2 M4 10 Pan head Screws 5 Figure B o4o0005 o4o0007 o4o0009 100 034 079 EZZ020568D SPAT35095 A 2 SPAT35097 1 M4 10 Pan head Screws 5 Figure B o4...

Page 22: ...This page intentionally blank 6 External Heatsink Option Part Numbers by Drive Model 22 YASKAWA V1000 J1000 AC Drive External Heatsink Kit Option Manual EZZ020568 ...

Page 23: ...ANUAL NO TM V1000SW 029 Published in U S A March 2013 13 3 Date of publication Date of original publication Revision number 1 Example Date of Publication Revision Number Section Revised Content September 2013 First Edition 7 Revision History YASKAWA V1000 J1000 AC Drive External Heatsink Kit Option Manual EZZ020568 23 ...

Page 24: ...7 Revision History This Page Intentionally Blank 24 YASKAWA V1000 J1000 AC Drive External Heatsink Kit Option Manual EZZ020568 ...

Page 25: ......

Page 26: ... Lorong Chuan 04 01 New Tech Park 556741 Singapore Phone 65 6282 3003 Fax 65 6289 3003 http www yaskawa com sg YASKAWA ELECTRIC SHANGHAI CO LTD No 18 Xizang Zhong Road 17F Harbour Ring Plaza Shanghai 200001 China Phone 86 21 5385 2200 Fax 86 21 5385 3299 http www yaskawa com cn YASKAWA ELECTRIC SHANGHAI CO LTD BEIJING OFFICE Room 1011 Tower W3 Oriental Plaza No 1 East Chang An Ave Dong Cheng Distr...