Synergy Series Operation Guide (v18)
Control Panel Introduction • 2–13
•
Within MLE 1 and MLE 2,
by themselves
, the Background and Preset buses are
electronically the farthest upstream, Key 1 is displayed mid stream and Key 2 is
displayed downstream.
~
Visually, all images on the background buses appear
behind
both keyers.
~
In the default state, a key enabled on Key 1 is displayed visually
over
the two
background buses (and all transitions), but visually
under
Key 2.
~
In the default state, a key enabled on Key 2 is displayed visually
over
the
background buses and Key 1.
~
If the
KEY OVER
button is pressed in Key 1, the priority is changed and Key 1 is
displayed visually
over
Key 2.
•
Within MLE 3 itself, the Program and Preset buses are electronically the farthest
upstream, DSK 1 is displayed mid stream and DSK 2 is displayed downstream.
~
Visually, all images on the background buses appear
behind
both DSKs.
~
A key enabled on DSK 1 is displayed visually
over
the background buses (and all
transitions), but visually
under
DSK 2. A key enabled on DSK 2 is displayed
visually
over
the background buses and DSK 1.
~
The
Fade to Black
module is electronically downstream of the entire switcher.
Regardless of the MLE selected on air,
Fade to Black
will visually take any
switcher MLE to black.
•
When MLE 1 is
re-entered
into MLE 2 or MLE 3, or when MLE 2 is re-entered into
MLE 3, the rules for upstream and downstream apply.
~
Visually, all images on MLE 1 (including backgrounds and keys) appear
behind
MLE 2 and MLE 3.
~
Visually, all images on MLE 2 (including backgrounds and keys) appear
over
MLE
1, but
under
and MLE 3.
~
Visually, all images on MLE 3 and the DSKs appear
over
MLE 1 and MLE 2.
•
When MLE 2 is re-entered
upstream
into MLE 1 (a condition shown in dotted lines on
the illustration above), the rules for upstream and downstream are slightly changed.
~
Visually, all images on the re-entered MLE appear
under
the destination (upstream)
MLE’s two keyers — regardless of the bus on which the MLE is re-entered. The
re-entered MLE moves upstream electronically — visually behind all downstream
MLE’s (except itself).
Operating
Tip
You can also change the priority of the two keyers in the
Key Setup
Menus
by toggling the
Key Over
softkey between
On
and
Off
. Refer
” on page 7-20 for more information.
Summary of Contents for SYNERGY 4000DR-003
Page 1: ...Ross Video Limited Operation Guide Volume I Software Issue 18...
Page 10: ......
Page 42: ...1 26 Introduction Synergy Series Operation Guide v18...
Page 64: ...2 22 Control Panel Introduction Synergy Series Operation Guide v18...
Page 132: ...4 54 Switcher Basics Synergy Series Operation Guide v18...
Page 242: ...7 68 Keying Synergy Series Operation Guide v18...
Page 280: ...8 38 Memory Functions and More Synergy Series Operation Guide v18...
Page 310: ...GL 4 Glossary of Terms Synergy Series Operation Guide v18...
Page 332: ...IX 22 Index Synergy Series Operation Guide v18...