10
10-180
MULTIJUNCTION TIMERS
10.8 TOU (Output-Related 24-Bit Timer)
32180 Group User’s Manual (Rev.1.0)
Figure 10.8.9 Typical Operation in PWM Output Mode
Count clock
Counter
H'FFFF
H'0000
Enabled
(by writing to the enable bit
or by external input)
F/F output
Underflow
(first time)
Interrupt request
due to underflow
Enable bit
Note: • This diagram does not show detailed timing information.
Reload 0 register
H'A000
Underflow
(second time)
H'(C000-1)
Data inverted
by underflow
Data inverted
by enable
H'(A000-1)
Data inverted
by underflow
Reload 1 register
H'C000
H'A000
PWM output period
H'C000
H'A000
Count down from the
reload 0 register
set value
One count clock equivalent delay
Undefined
value
H'(A000-1)
One count clock equivalent delay
One count clock equivalent delay
Count down from the
reload 1 register
set value
Count down from the
reload 0 register
set value