10
10-167
MULTIJUNCTION TIMERS
10.8 TOU (Output-Related 24-Bit Timer)
32180 Group User’s Manual (Rev.1.0)
TOU0_0 Reload 1 Register (TOU00RL1)
<Address: H'0080 0794>
TOU0_1 Reload 1 Register (TOU01RL1)
<Address: H'0080 079C>
TOU0_2 Reload 1 Register (TOU02RL1)
<Address: H'0080 07A4>
TOU0_3 Reload 1 Register (TOU03RL1)
<Address: H'0080 07AC>
TOU0_4 Reload 1 Register (TOU04RL1)
<Address: H'0080 07B4>
TOU0_5 Reload 1 Register (TOU05RL1)
<Address: H'0080 07BC>
TOU0_6 Reload 1 Register (TOU06RL1)
<Address: H'0080 07C4>
TOU0_7 Reload 1 Register (TOU07RL1)
<Address: H'0080 07CC>
TOU1_0 Reload 1 Register (TOU10RL1)
<Address: H'0080 0B94>
TOU1_1 Reload 1 Register (TOU11RL1)
<Address: H'0080 0B9C>
TOU1_2 Reload 1 Register (TOU12RL1)
<Address: H'0080 0BA4>
TOU1_3 Reload 1 Register (TOU13RL1)
<Address: H'0080 0BAC>
TOU1_4 Reload 1 Register (TOU14RL1)
<Address: H'0080 0BB4>
TOU1_5 Reload 1 Register (TOU15RL1)
<Address: H'0080 0BBC>
TOU1_6 Reload 1 Register (TOU16RL1)
<Address: H'0080 0BC4>
TOU1_7 Reload 1 Register (TOU17RL1)
<Address: H'0080 0BCC>
TOU2_0 Reload 1 Register (TOU20RL1)
<Address: H'0080 0C94>
TOU2_1 Reload 1 Register (TOU21RL1)
<Address: H'0080 0C9C>
TOU2_2 Reload 1 Register (TOU22RL1)
<Address: H'0080 0CA4>
TOU2_3 Reload 1 Register (TOU23RL1)
<Address: H'0080 0CAC>
TOU2_4 Reload 1 Register (TOU24RL1)
<Address: H'0080 0CB4>
TOU2_5 Reload 1 Register (TOU25RL1)
<Address: H'0080 0CBC>
TOU2_6 Reload 1 Register (TOU26RL1)
<Address: H'0080 0CC4>
TOU2_7 Reload 1 Register (TOU27RL1)
<Address: H'0080 0CCC>
b0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
b15
TOU00RL1–TOU07RL1, TOU10RL1–TOU17RL1, TOU20RL1–TOU27RL1
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
<After reset: Undefined>
b
Bit Name
Function
R
W
0–15
TOU00RL1–TOU07RL1,
16-bit reload register value
R
W
TOU10RL1–TOU17RL1,
TOU20RL1–TOU27RL1
Note: • This register must always be accessed in halfwords.
During PWM output and single-shot PWM output modes, TOU operates as a 16-bit timer. Use the reload 1
register to set the 16-bit value to be loaded into the counter when the count value set in the reload 1 register has
underflowed.
The content of the reload 1 register is loaded into the counter in the following cases:
• When the count value set in the reload 0 register has underflowed in PWM output mode
Simply because data is written to the reload register does not mean that the data is loaded into the counter. The
counter is loaded with data in only the above cases.
If the value ‘FFFF’ is set in the reload register, F/F output will not be inverted, making it possible to produce a 0%
or 100% duty-cycle PWM output. For details, see Section 10.8.17, “0% or 100% Duty-Cycle Wave Output during
PWM Output and Single-shot PWM Output Modes.”
During single-shot output, delayed single-shot output and continuous output modes, the reload 0 and reload 1
registers are combined for use as a 24-bit reload register. For details, see Section 10.8.6, Paragraph (1), “TOU
reload registers during single-shot output, delayed single-shot output and continuous output modes.”
Summary of Contents for M32R/ECU Series
Page 17: ...12 This page is blank for reasons of layout...
Page 712: ...CHAPTER 18 OSCILLATOR CIRCUIT 18 1 Oscillator Circuit 18 2 Clock Generator Circuit...
Page 794: ...CHAPTER 22 TYPICAL CHARACTERISTICS...
Page 796: ...APPENDIX 1 MECHANICAL SPECIFICAITONS Appendix 1 1 Dimensional Outline Drawing...
Page 798: ...APPENDIX 2 INSTRUCTION PROCESSING TIME Appendix 2 1 32180 Instruction Processing Time...
Page 802: ...APPENDIX 3 PROCESSING OF UNUSED PINS Appendix 3 1 Example Processing of Unused Pins...