10
10-158
MULTIJUNCTION TIMERS
10.8 TOU (Output-Related 24-Bit Timer)
32180 Group User’s Manual (Rev.1.0)
10.8.4 TOU Control Registers
TOU0 Control Register 0 (TOU0CR0)
<Address: H’0080 07DA>
b0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
b15
TOU00M0
TOU01M0
TOU02M0
TOU03M0
TOU04M0
TOU05M0
TOU06M0
TOU07M0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
<After reset: H’0000>
b
Bit Name
Function
R
W
0, 1
TOU00M0 (TOU0_0 operation mode select 0 bit)
00: Single-shot output mode
R
W
2, 3
TOU01M0 (TOU0_1 operation mode select 0 bit)
01: Single-shot PWM output mode
4, 5
TOU02M0 (TOU0_2 operation mode select 0 bit)
or delayed single-shot output mode (Note 1)
6, 7
TOU03M0 (TOU0_3 operation mode select 0 bit)
10: Continuous output mode
8, 9
TOU04M0 (TOU0_4 operation mode select 0 bit)
11: PWM output mode
10, 11
TOU05M0 (TOU0_5 operation mode select 0 bit)
12, 13
TOU06M0 (TOU0_6 operation mode select 0 bit)
14, 15
TOU07M0 (TOU0_7 operation mode select 0 bit)
Note 1: Use TOU0 Control Register 1 to select between these two modes.
Notes: • This register must always be accessed in halfwords.
• Operation mode can only be set or changed while the counter is inactive.
TOU0 Control Register 1 (TOU0CR1)
<Address: H’0080 07D8>
b0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
b15
TOU0CKS
TOU00M1 TOU01M1 TOU02M1 TOU03M1
TOU05M1 TOU06M1 TOU07M1
TOU04M1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
<After reset: H’0000>
b
Bit Name
Function
R
W
0
TOU0CKS
0: Use prescaler 3
R
W
TOU0 clock source select bit
1: Use external clock (TIN24)
1–7
No function assigned. Fix to "0".
0
0
8
TOU00M1 (TOU0_0 operation mode select 1 bit)
0: Single-shot PWM output mode
R
W
9
TOU01M1 (TOU0_1 operation mode select 1 bit)
1: Delayed single-shot output mode
10
TOU02M1 (TOU0_2 operation mode select 1 bit)
11
TOU03M1 (TOU0_3 operation mode select 1 bit)
12
TOU04M1 (TOU0_4 operation mode select 1 bit)
13
TOU05M1 (TOU0_5 operation mode select 1 bit)
14
TOU06M1 (TOU0_6 operation mode select 1 bit)
15
TOU07M1 (TOU0_7 operation mode select 1 bit)
Notes: • This register must always be accessed in halfwords.
• Operation mode can only be set or changed while the counter is inactive.
TOU0 Control Registers 0 and 1 are used to select operation modes of TOU0_0–7.
To select prescaler 3 as the clock source for TOU0, make sure the TID0 Control & Prescaler 3 Enable Register’s
prescaler 3 enable bit is set to "1". For details, see Section 10.7.3, “TID Control & Prescaler Enable Registers.”
Summary of Contents for M32R/ECU Series
Page 17: ...12 This page is blank for reasons of layout...
Page 712: ...CHAPTER 18 OSCILLATOR CIRCUIT 18 1 Oscillator Circuit 18 2 Clock Generator Circuit...
Page 794: ...CHAPTER 22 TYPICAL CHARACTERISTICS...
Page 796: ...APPENDIX 1 MECHANICAL SPECIFICAITONS Appendix 1 1 Dimensional Outline Drawing...
Page 798: ...APPENDIX 2 INSTRUCTION PROCESSING TIME Appendix 2 1 32180 Instruction Processing Time...
Page 802: ...APPENDIX 3 PROCESSING OF UNUSED PINS Appendix 3 1 Example Processing of Unused Pins...