10
10-137
MULTIJUNCTION TIMERS
10.6 TML (Input-Related 32-Bit Timer)
32180 Group User’s Manual (Rev.1.0)
(2) Precautions on using TML measure input
The following describes precautions to be observed when using TML measure input.
• If measure event input and write to the counter occur in the same clock period, the write value is set in the
counter, whereas the up-count value (before being rewritten) is latched into the measure register.
• If clock bus 1 is selected and any clock other than BCLK/2 is used for the timer, the counter cannot be
written normally. Therefore, when using any clock other than BCLK/2, do not write to the counter.
• If clock bus 1 is selected and any clock other than BCLK/2 is used for the timer, the value captured into the
measure register is one count larger the counter value. During the count clock to BCLK/2 period interval,
however, the captured value is exactly the counter value.
The diagram below shows the relationship between counter operation and the valid data that can be cap-
tured.
Counter
B
A
C
D
E
F
A
B
C
D
E
• When BCLK/2 is selected
BCLK/2
Captured
Counter
B
A
C
• When clock bus 1 is selected
BCLK/2
Count clock
Captured
B
C
D
F
Figure 10.6.3 Mistimed Counter Value and the Captured Value
Summary of Contents for M32R/ECU Series
Page 17: ...12 This page is blank for reasons of layout...
Page 712: ...CHAPTER 18 OSCILLATOR CIRCUIT 18 1 Oscillator Circuit 18 2 Clock Generator Circuit...
Page 794: ...CHAPTER 22 TYPICAL CHARACTERISTICS...
Page 796: ...APPENDIX 1 MECHANICAL SPECIFICAITONS Appendix 1 1 Dimensional Outline Drawing...
Page 798: ...APPENDIX 2 INSTRUCTION PROCESSING TIME Appendix 2 1 32180 Instruction Processing Time...
Page 802: ...APPENDIX 3 PROCESSING OF UNUSED PINS Appendix 3 1 Example Processing of Unused Pins...