30
Installing a Multi-Module Library
Positioning the System Unit
For more information on location specifications, see the
Scalar i6000 Planning Guide
.
1
Verify the placement of the system unit.
2
Verify the following:
•
There is an AC outlet within 10 feet (3.05 m) of the control module’s location.
•
There is adequate clearance for the access and service doors.
•
All raised floor tiles have been cut out accordingly to accommodate the power, SCSI, Fibre, and
Ethernet cables to any of the modules.
3
Position the system unit in its intended location.
4
Verify that the system unit is positioned correctly.
5
Ensure that the leveling legs are not resting on tiles that will need to be raised to accommodate cables
after the system unit has been installed.
Lowering the System Unit Leveling Legs
Required tools: 24 mm open end wrench, 6 mm hex wrench or 16 mm open end wrench.
1
On only the four outer edge corner legs of the system unit, use the 24 mm open end wrench to loosen
the four locking nuts.
2
Lower the four outer edge corner legs by hand until the legs touch the floor. You may need to use the
6 mm hex wrench or 16 mm open end wrench to turn the legs if the threads do not turn freely.
Note
The control module is at the left end of a multi-module library.
CAUTION
If you do not loosen the locking nuts, you may strip the threads on the
leveling legs during movement.
Note
To ensure even weight distribution on the legs, it is very important that the
lowered legs be brought into contact with the floor without lifting the system
unit. You can verify whether a leg is in contact with the floor by attempting
to slide a piece of paper underneath it.
Summary of Contents for Scalar i6000
Page 20: ...8 About This Guide and Your Product...
Page 38: ...26 Installing a Stand Alone Control Module...
Page 104: ...92 Installing a Multi Module Library...
Page 156: ...144 Installing Cartridges...
Page 164: ...152 Setting up Your Library for Access...
Page 242: ...230 Configuring the Library...
Page 304: ...292 Adding Optional Hardware eight 2 5 mm screws...
Page 318: ...306 Adding Optional Hardware...
Page 336: ...324 Installation Testing and Verification Figure 35 Example Test Log Output...
Page 356: ...344 Testing and Calibrating the Digital Level...
Page 362: ...350 LBX Board and Terminator...
Page 380: ...368 Glossary...
Page 384: ...372 Index...