296
Adding Optional Hardware
54
Close the I/E stations and all access doors.
55
Press the
Power
switch on the operator panel.
56
Log on to the library as a service user. See the
Scalar i2000 / i6000 Maintenance Guide
.
57
From the LMC, run
Configure
by clicking
Tools
→
Teach
→
Configure
.
See the
Scalar i6000 User’s Guide
for more information.
58
After completing the configure process, run
Calibrate
click
Tools
→
Teach
→
Calibrate.
59
Run a complete Install Verification Test est to verify proper installation by clicking
Tools > Verification
Tests > Install.
The results appear on the
Verification Tests
dialog box after the test is complete.
60
If using Auto Teach, make certain to turn this feature back on.
61
You must modify and configure any existing partitions that include resources altered or removed by the
change in the expansion module physical configuration to incorporate the new I/E station.
In the LMC, click
Setup
→
Partitions
→
Configure
to modify partitions and create new ones.
See the
Scalar i6000 User’s Guide
for more information about working with partitions.
62
Assign the new I/E station and storage slot in the new access to their appropriate partitions.
63
If the magazines on the access door are assigned to partitions, you must import all the cartridges you
removed from the previous expansion module access door to the appropriate partitions in the new
access door.
64
If there is not enough space for all the cartridges from the previous access door due to the larger I/E
station, reassign the access door’s storage slots to appropriate partitions.
65
If appropriate, perform
Partitions Defragmentation
. Click
Tools
→
Partitions Defragmentation
.
The
Partitions Defragmentation
dialog box appears. This dialog box shows a graphical representation
of the tape magazines in the library. Magazines are color-coded to indicate which partition they belong
to. If the library has more than one module, click the arrow buttons to display the next or previous
module. If one or more partitions are fragmented, you can defragment them.
66
For more information on the I/E station features, see the
Scalar i6000 User’s Guide.
Summary of Contents for Scalar i6000
Page 20: ...8 About This Guide and Your Product...
Page 38: ...26 Installing a Stand Alone Control Module...
Page 104: ...92 Installing a Multi Module Library...
Page 156: ...144 Installing Cartridges...
Page 164: ...152 Setting up Your Library for Access...
Page 242: ...230 Configuring the Library...
Page 304: ...292 Adding Optional Hardware eight 2 5 mm screws...
Page 318: ...306 Adding Optional Hardware...
Page 336: ...324 Installation Testing and Verification Figure 35 Example Test Log Output...
Page 356: ...344 Testing and Calibrating the Digital Level...
Page 362: ...350 LBX Board and Terminator...
Page 380: ...368 Glossary...
Page 384: ...372 Index...