316
Installation Testing and Verification
Vertical Alignments
The vertical alignments graphical report shows the results for test of vertical alignment of tape magazines
on the drive-side and door-side of each frame, and for vertical alignment of each I/E station.
•
If the graphical report shows a failed result for the drive-side or door-side, make sure that all tape
magazines are installed properly on that side and that the calibration targets are correctly snapped
on to the magazines.
•
If the graphical report shows a failed result for the I/E station, make sure the I/E station and front
door are completely shut.
•
If running the test again still generates failed results, realign the middle X-axis rail and check the
alignment of the top and bottom X-axis rails at the location of the failure.
Figure 28
Vertical Alignments Graphical Report