342
Testing and Calibrating the Digital Level
8
Turn the level around so the display is facing away from you and the screw on the back of the level is
at the top. Ensure that the level is positioned in the same spot as
. Wait 10 seconds for the level
to completely settle. Without moving the level, gently press the
HOLD
button until a
[ 6 ]
appears on the
display.
9
Rotate the level end-for-end so the display is facing you and the text on the face of the level can be read
from top to bottom. Ensure that the level is positioned in the same spot as
. Wait 10 seconds for
the level to completely settle. Without moving the level, gently press the
HOLD
button until a
[ 7 ]
appears on the display.