46
Installing a Multi-Module Library
2
Loosen the eight 2.5 mm screws attaching the X-axis channel to the module.
3
Push the X-axis channel and middle X-axis rail to the left until the X-axis rail of the expansion module
contacts the X-axis rail of the module on the left.
4
Hold the X-axis channel so that the adjacent X-axis rails are touching each other and tighten the eight
2.5 mm screws.
5
Loosen the X-axis rail 3 mm screws that were tightened
Aligning the Middle X-Axis Rail
1
Loosen the five 8 mm nuts on the X-axis rail alignment tool (part number 3-00147-01). Once the nuts
are loose, separate the two metal bars of the tool and insert the back bar into the X-axis rail.
2
Position the middle of the X-axis rail alignment tool over the junction point in the rails.
If the X-axis rail tool is positioned correctly you should be able gain access to the 3 mm screws through
the holes in the tool.
2.5 mm screws
2.5 mm screws
alignment pins
8 mm nuts
X-axis alignment tool
middle X-axis rails
junction
3 mm screws
x-axis channels
Summary of Contents for Scalar i6000
Page 20: ...8 About This Guide and Your Product...
Page 38: ...26 Installing a Stand Alone Control Module...
Page 104: ...92 Installing a Multi Module Library...
Page 156: ...144 Installing Cartridges...
Page 164: ...152 Setting up Your Library for Access...
Page 242: ...230 Configuring the Library...
Page 304: ...292 Adding Optional Hardware eight 2 5 mm screws...
Page 318: ...306 Adding Optional Hardware...
Page 336: ...324 Installation Testing and Verification Figure 35 Example Test Log Output...
Page 356: ...344 Testing and Calibrating the Digital Level...
Page 362: ...350 LBX Board and Terminator...
Page 380: ...368 Glossary...
Page 384: ...372 Index...